Ensure air shutter opening is free of lint or other obstructions.
Check that the logs are correctly positioned. Open
air shutter to increase the primary air.
Check the input rate: check the manifold pressure and orifi ce
size as specifi ed by the rating plate values.
Check that the door gasketing is not broken or missing and
that the seal is tight.
Check that both vent liners are free of holes and well sealed
at all joints.
Check that minimum rise per foot (meter) has been adhered
to for any horizontal venting.
Clean the glass with a recommended gas appliance glass
cleaner.
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may
become permanently marked.
Ensure exhaust bracket gasket seal.
Check door seal and relief fl ap seal.
Check for chimney blockage.
Check that chimney is installed to building code.
Room is in negative pressure; increase fresh air supply.
Check cap gasket on the fl ue pipe assembly.
-
Reverse.
Replace.
-
Check for ground (short); repair ground or replace wire.
Replace.
42.3_2G
TEST SOLUTION
Clean the glass with a recommended gas appliance
glass cleaner.
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may
become permanently marked.
Ensure exhaust bracket gasket seal.
Check door seal and relief fl ap seal.
Check for chimney blockage.
Check that chimney is installed to building code.
Room is in negative pressure; increase fresh air
supply.
Check cap gasket on the fl ue pipe assembly.
down.
-
Reverse.
Replace.
grounding.
-
Check for ground (short); repair ground or replace wire.
Replace.
42.3_3
Summary of Contents for CB30NTR
Page 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Page 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Page 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Page 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Page 83: ......
Page 84: ......