26
W415-1398 / C / 06.15.17
EN
26 FT (7.9m) < 40 FT (12.2m)
3.11
REAR
EXIT
A.
R
emove the safety screen and glass front, refer to " SAFETY SCREEN / DOOR REMOVAL AND
INSTALLATION" section.
B.
Remove the contents from the firebox and set aside, you will need the exhaust flue collar from the top of the
log
carton.
DEFLECTOR DÉFLECTEUR
C.
To ease assembly, remove the four hex head screws
securing the deflector from inside the top front of the firebox, refer to
Figure 1.
Fig. 2
D.
Place the gasket (provided) over the 4" (102mm) flue collar assembly and
bend along perforation.
E.
From inside the firebox, insert the 4" (102mm) flue collar through the back
of the firebox. Install the rear exit shield onto the 4" (102mm) flue collar,
see "REAR EXIT SHIELD" section for installation instructions.
F.
Secure the flue collar assembly, gasket and rear exit shield using the four
hex head 3/8" thread cutting screws, refer to Figure 2.
NOTE: Do not
overtighten. The gasket needs only to be snug against the firebox.
G.
Reattach the deflector using the four screws and install the log set, glass door and
safety screen.
WARNING
FAILURE TO CREATE A SEAL TO THE FIREBOX WITH THE EXHAUST COLLAR ASSEMBLY WILL
CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY
DAMAGE.
!
Summary of Contents for CB30NTR
Page 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Page 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Page 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Page 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Page 83: ......
Page 84: ......