background image

1

OPERATION AND INSTALLATION MANUAL

Multi-fuel
Burcott
Fireplace inset stove

Summary of Contents for Burcott

Page 1: ...1 OPERATION AND INSTALLATION MANUAL Multi fuel Burcott Fireplace inset stove ...

Page 2: ...ocal regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing and using fireplaces and wood burning stoves please see the relevant building regulations that apply to the country in which Burcott fireplace inset stove has been approved as well as the relevant information on the correct use ...

Page 3: ...CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove because this can cause the stove to emit fumes into the room Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the coarse of installation then please seek specialist gu...

Page 4: ...revent smoke problems into the room Tested Gas flow rates flue gas temperatures Flue gas flow rate Wood coal Test flue gas temperature wood coal pascals of pressure Burcott 2 8 4 0g sec 217 184 deg C 12 pa NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternately the calculation procedure given in...

Page 5: ...stove If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated sta...

Page 6: ...lue or flue pipe Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue pipe Your appliance needs to be maintained routinely the throat plate baffle should be cleaned regularly monthly The flue pipe can be cleaned using a flexible brush Only Use a damp cloth on external surfaces Over time the glass may become dirty clean with a dam...

Page 7: ...earth only Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or on the hearth and walls adjacent to the hearth should comply with the guidance on the separation of combustible material given in Building Regulati...

Page 8: ...e installation of the stove and fit the collar back to the stove once the stove has been installed insitu Commissioning and handover Ensure loose parts are fitted in accordance with the instructions given in the instruction booklet On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out a small fire may be lit to check that smoke and fumes are ta...

Page 9: ... coming away from the door Once the heat resistant paint has hardened the smell will disappear This stove is NOT designed to be used with the door open the stove door must be kept closed except when lighting the stove adding firewood or removing ash in order to prevent flue gases from escaping Lighting your appliance Quality Firelighters should be used when lighting the stove Never use metholated ...

Page 10: ...mall quantity of fuel in the combustion chamber 2 Fully open the secondary air control Fully open primary air below door of stove The stove s air controls are now fully open Light firelighters and securely close door 3 With the fire established open the door And fill chamber with fuel see weight table on page 3 do not overload do not cover tertiary air ports Reloading is approximately every 2 hour...

Page 11: ...le for use as firewood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood Do not burn liquid fuels drift wood finished sawn wood pallet wood chipboard plywood varnished wood or plastic coated wood wood treated with preservatives or house hold waste SOLID SMOKELESS FUELS Burcott fireplace inset stove model is suitable for use with good quality smo...

Page 12: ...ion manual 4 Ash Pan Secondary air Open Right pull open Left closed Tertiary air Permanently open Primary air Right open Left closed To Open door lift handle To close push door closed and push handle down until located When opening the door of your Mendip stove always wear the glove that is provided to protect your hand from possible heat The handle has push pull motion as shown above When shuttin...

Page 13: ...therm paint lacquer spray available from your Mendip dealer To clean the outside of the stove use a dry cloth Sweeping your chimney Ensure that your appliance flue ways and chimney are swept regularly This can be incorporated in the service regime of your appliance Regular sweeping is essential and means at least once a year for smokeless fuels and a minimum of twice a year for bituminous coal woo...

Page 14: ...e fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 Smoke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the height of the chimney relative to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regul...

Page 15: ...15 ...

Page 16: ...toves Ltd Unit H2 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Mendip Stoves Ltd 2013 Burcott v3 2013 ...

Reviews: