4
STOVE PERFORMANCE & TESTING
MENDIP STOVES BURCOTT Fireplace inset stove is approved and tested in accordance with EN 13240.
Log length
Wood reload
Weight wood load
Coal reload
Weight coal (anth)
Burcott
20cm
1hr
875 g
2hr
900g
Stove model
Weight & Nominal heat output for Wood and Smokeless fuels
Chimney Connection
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught to
clear the products of combustion and prevent smoke problems into the room.
Tested Gas flow rates flue
gas temperatures
Flue gas flow rate
Wood /coal
Test flue gas temperature
wood /coal
@ pascals of pressure
Burcott
2.8/4.0g/sec
217/184 deg C
12 pa
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the
chimney should be satisfactory. Alternately the calculation procedure given in BS 5854:1980 may be used as the basis for
deciding whether a particular chimney design will provide sufficient draught.
Output
wood fuel
Efficiency
CO@13%
o2
Recommended
for smoke control
Oct 2012
Output coal
fuel
Efficiency
CO@13% o2
Burcott
4.1kw
83%
0.38
no
3.9kw
79%
0.36