Installation Instructions
Expansion Module and Expansion Element
Program 0815
MV0815-0005a-EN
www.conductix.com translated document
page 20 of 26
The conductor rail ends of the expansion module are connected to the preinstalled conductor rail using rail connectors
(see section 6.3.3.2 in BAL0185-0002-EN):
Fig. 27: Push the rails onto the connector
Fig. 28: Correct position of the clamp
Fig. 29: Incorrect position of the clamp
Fig. 30: Tighten the connector
Fig. 31: Slide the connector cap over the rail connection
Tighten the connector
with a 3-mm hex
screwdriver to
2 Nm
.