Installation Instructions
Expansion Module and Expansion Element
Program 0815
MV0815-0005a-EN
www.conductix.com translated document
page 25 of 26
7.2.3
Case 3: Steel Conductor Rail on Steel Load Profile
No expansion module needed, since there is no differential expansion. Except for building expansion joints:
see chapter 5.1
7.2.4
Case 4: Steel Conductor Rail on Aluminum Load Profile
The aluminum load profile expands more during changes in temperature than does the steel conductor rail.
Fig. 43: Steel conductor rail on aluminum load profile
NOTE!
After adjusting the gap, be sure that it cannot slip more during later installa-
tion.
7.3
Installing an Air Gap
Air gaps without expansion distance and without electrical bypass
Air gaps can be used anywhere. When used in a curve, two additional hanger clamps are required. Gaps can also be
retrofitted.
To do this, cut a 46 mm piece out of the rail at the desired point
Deburr the rail ends cleanly (see BAL0815-0002-EN)
Fig. 44: Clamp inserted into rail