Installation Instructions
Expansion Module and Expansion Element
Program 0815
MV0815-0005a-EN
www.conductix.com translated document
page 13 of 26
Fig. 11: Load profile with hanger clamps and mounted rails (segment)
The expansion module, including the preinstalled hanger clamps, clips into the hanger clamps permanently mounted
on the load profile. The hanger clamps preinstalled on the expansion module remain on the expansion module and are
not connected to the load profiles (floating installation).
NOTE!
The hanger clamps fastened to the load profile must have enough distance
from the middle of the hanger clamp to the middle of the expansion element of
the expansion module (at least 100 mm)!
Fig. 12: Insert expansion module with hanger clamp into existing hanger clamp
If overlaps are possible with the mounted conductor rail and/or any hanger clamps already installed, proceed
as follows:
If necessary, the hanger clamps must be offset before installing the expansion module (Warning:
the distance between the individual hanger clamps may not be > 500 mm. Install any additional
hanger clamps before or after the installed expansion module!)