7 Troubleshooting
Problem
:
Condre RAID
is not properly identified by the SCSI adapter during the
initialization of you computer system.
Possible Cause:
The SCSI ID set for the
Condre RAID
is used by another SCSI device
attached to the same SCSI adapter.
Fix
: Through the Configuration Mode select SCSI Params, then Set SCSI ID, and
specify a different SCSI ID. Also, most SCSI host adapters provide a onboard ROM
BIOS, or software utility, that displays the devices attached and their SCSI ID.
Disconnect the
Condre RAID
from the SCSI host adapter and during the system boot, or
by running the utility, note the SCSI ID already in use. This will select a SCSI ID for
the
Condre RAID
.
Problem
: The
Condre RAID
is identified at all SCSI ID.
Possible
Cause
: The SCSI ID set for the
Condre RAID
is identical to the reserved SCSI
ID used by the SCSI adapter in your computer system.
Fix
: Use the Configuration Mode to configure the
Condre RAID
for a different SCSI ID.
Remember the majority of SCSI host adapter reserves SCSI ID 7 for the adapter ID.
Problem
: The
Condre RAID
is not been detected by the SCSI host adapter.
Possible
Cause
: Incorrect termination in a daisy chain configuration or a loose cable in
a stand-alone configuration.
Fix
: In a daisy chain configuration verify only the SCSI host adapter and the last SCSI
device is terminated. To change the termination settings of the
Condre RAID
use the
SCSI Params menu and SCSI Termination option to enable or disable termination.
Problem
: Unable to access the
Condre RAID
after the operating system boots up.
Possible Cause
: The
Condre RAID
is not configured.
Fix
: Make sure the
Condre RAID
is configured for a RAID level. If no RAID level is
configured the operating system will not detect the
Condre RAID
as a disk drive.
Problem
: Unable to access the Configuration Mode using the remote terminal
interface.
Possible Cause
: The terminal communications settings are not matching the settings
of the
Condre RAID
RS-232 interface.
54
Fix
: The default settings for the RS-232 port are 19200 Baud rate, 8 Data bits, 1 Stop
bit, No Parity, and XON/XOFF Flow control. Make sure the terminal is configured for