22
6.2
Operating displays
Operating displays appear in black letters on a blue background.
6.1.2
Parameter setting
The setting
of cycles (regeneration process) and
parameters
is a necessary prerequisite for the correct operation of the system. The control unit is preset
ex-works to match the size. Check all settings and use the corresponding size-specific tables
in the appendix. These tables contain all the values to be set, including the quick setting from
section 1.1.
6.3 Regeneration
6.3.1
Triggering immediate regeneration
Press the „REGEN“ button for at least 5 seconds.
The control unit sets the currently operational valve at the various backwash cycles in
accordance with the current flow rate display. It is possible to switch to the next cycle during
regeneration by briefly pressing the „REGEN“ button. After all cycles have been completed,
the valve returns to the operating state.
Control unit
Meaning
Display
Time when filter A is in operation and filter B is
on standby.
Time of day
A
7:35
Time when filter B is in operation and filter A is
on standby.
Time of day
B
8:35
The residual amount of soft water still available
in filter A operating cycle
Remaining capacity
A
8:40
Duration until a regeneration is forcibly
triggered, if – depending on the quantity – no
regeneration is triggered during this time.
Days to regeneration
A
8:40
Current flow rate in l/min.
Flow rate
B
Language
Summary of Contents for CONDAIR SOFT
Page 31: ...31 Appendix 9 3 Electrical connection...
Page 48: ...48 9 5 1 Soft 60 System drawing Appendix...
Page 49: ...49 9 5 2 Soft 120 System drawing Appendix...
Page 50: ...50 9 5 3 Soft 200 System drawing Appendix...
Page 51: ...51 9 5 4 Soft 320 System drawing Appendix...
Page 52: ...52 9 5 5 Soft 400 System drawing Appendix...
Page 54: ...54 Notes...
Page 55: ...55 Notes...