12
4.
Installation and Assembly
4.1
Installation
4.1.1
Installation site requirements
The space required for the system is specified in the dimensions provided in the
technical data.
The installation room must meet the ambient conditions according to the technical data.
The installation surface must be level and horizontal and have sufficient load-bearing
capacity.
The room must be well ventilated and frost-proof.
The necessary electrical connections, as specified in the technical data, must be available
on-site at a maximum distance of 1 m from the system.
Depending on the system size, a control air connection must be available.
The raw water connection must be provided with a shut-off device.
The on-site waste water connection must be provided as a free output in accordance with
EN 1717 and must be installed and usable in the required cross-section. Observe the
waste water capacity specified in the technical data.
When using drinking water as the raw water of a softening system, the following must
be observed:
An appropriately suitable fuse fitting for system separation must be installed by the customer
on-site. Upon request, the manufacturer may add silver resin or supply a chlorine cell
for installation in the brine exchange hose to enable automatic disinfection (subject to
an extra charge).
WARNING!
To prevent flooding due to leakage, the installation room must be equipped with a floor drain
and/or a leakage monitor with a corresponding alarm.
Technical Data / Product Description
INSTRUCTION
For installation and assembly, refer to the existing plans and drawings from the
technical appendix.
INSTRUCTION
In accordance with EN 1717, softening systems may be equipped with the following safety
fittings in drinking water installations: free output or pipe isolator. It should also be noted
that DIN 19636 „Softening systems in drinking water installations“ requires the following
– page 2, point 4.7 Protection against germs: „Since softening systems tend to become
contaminated, especially in stop-start operation, this must be prevented by means of
suitable design or chemical-physical measures.“
Summary of Contents for CONDAIR SOFT
Page 31: ...31 Appendix 9 3 Electrical connection...
Page 48: ...48 9 5 1 Soft 60 System drawing Appendix...
Page 49: ...49 9 5 2 Soft 120 System drawing Appendix...
Page 50: ...50 9 5 3 Soft 200 System drawing Appendix...
Page 51: ...51 9 5 4 Soft 320 System drawing Appendix...
Page 52: ...52 9 5 5 Soft 400 System drawing Appendix...
Page 54: ...54 Notes...
Page 55: ...55 Notes...