60 - RocketLinx ES7528 Industrial Managed PoE Rack Mount User Guide
: 2000509 Rev. A
PD Status Detection
PD Status Detection
The following graphic illustrates how to configure IEEE 802.3at LLDP. Assume the PD is ready for the configuration for IEEE
802.3at LLDP, you only need to confirm the RocketLinx ES7528 configuration.
For example, connect the port of the RocketLinx ES7528 to the PD (ex. Port 4), set
PoE Mode
is
Enable
and
Powering Mode
is
802.3at(LLDP)
. When the RocketLinx ES7528 and the PD are ready to IEEE802.3at LLDP, IEEE 802.3at LLDP starts
operation. Refer to
PoE Status
on Page 61, to see the
PoE Status
page.
PD Status Detection
The RocketLinx ES7528 delivers a useful function – PD Status Detection. This
provides automatic detection of a remote device powered by the RocketLinx
ES7528. If the remote system crashes or is unstable, the RocketLinx ES7528
performs a system reboot by turning off and on again to trigger the remote
device. The following figure shows the web configuration interface for Power
over Ethernet PD Status Detection.
Apply
Click
Apply
to apply the settings.
Note: You must Save the settings (Page 137), if you want maintain these settings if the
RocketLinx ES7528 is powered off.
PD Status Detection
Description
PD Status Detection
Enable
/
Disable
PD Status Detection function.
IP Address
Type in the IP address that you want to detect.
Cycle Time(s)
This is the gap per detection in seconds.
Apply
Click
Apply
to apply the settings.
Note: You must Save the settings (Page 137), if you
want maintain these settings if the
RocketLinx ES7528 is powered off.
PoE Control
Description
DO NOT TOUCH DEVICE SURFACE DURING
PoE PROGRESS HIGH POWER FEEDING.