MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–9
7.3.1
MBT-5000 Base Unit Remote Commands and Queries
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Auto Fault
Recovery
AFR=
1 byte,
Command or Query.
BUC/BDC output is automatically muted in event of detected fault. If auto fault recovery is
enabled, it causes output to return to pre-fault mute condition if all faults are cleared.
If disabled, the output remains muted even if all faults are cleared.
Clearing of fault condition will not cause a switchover in a redundant system unless the currently
online unit is faulted; in which case, the newly unfaulted unit is brought online.
Default Value:
1
Example:
<1/AFR=1’cr’
>0001/AFR=’cr’’lf’
AFR =
AFR?
AFR*
AFR?
AFR=x
(Same format as
Command
arguments)
Clear All Stored
Events
CAE=
None
Command only.
Instructs unit to clear all Stored Events. This command takes no arguments.
Example:
<1/CAE=’cr’
>0001/CAE=’cr’’lf’
CAE=
N/A
N/A
Circuit
Identification
CID=
24 bytes,
Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed length of 24 characters.
Default value:
------------------------
Valid characters include:
Space ( ) * + – . / 0 9 and A thru Z
CID=
CID?
CID?
CID=x…x
(See Description of
Arguments)
Set RTC (Real-
Time-Clock)
Date
DAY=
6 bytes
Command or Query.
A command in the form ddmmyy, where:
dd = day of the month (between 01 and 31);
mm = month of the year (between 01 and 12); and
yy = year (between 00 and 99; i.e., 2000 to 2099)
Example:
<1/DAY=240403’cr’
>0001/DAY=’cr’’lf’
(date = April 24, 2003):
DAY=
DAY?
DAY*
DAY?
DAY=xxxxxx
(Same format as
Command
arguments)
Summary of Contents for MBT-5000
Page 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Page 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Page 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Page 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Page 137: ......
Page 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...