MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–17
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Remote Baud
Rate
SBR=
4 bytes
Command or Query.
Set remote baud rate as follows:
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud
19K2 = 19200 baud
38K4 = 38400 baud
Default Value:
9600
Example:
<1/SBR=9600’cr’
>0001/SBR=9600’cr’’lf’
Note:
When changing baud rates remotely the response to the command will be returned using
the same baud rate as that used to send the command.
SBR=
SBR?
SBR?
SBR=xxxx
(See format as
Command
arguments)
Serial Number
N/A
9 bytes
Query only.
Queries the unit 9-digit serial number. Unit returns its S/N in the form xxxxxxxxx.
Example:
SNO=176500143
N/A
SNO?
SNO=xxxxxxxxx
(See Description of
Arguments)
Remote
Address
SPA=
4 bytes
Command or Query.
Sets Physical Address - between 0001 to 9997. Resolution = 0001.
Example:
<1/SPA=0412’cr’
>0001/SPA=’cr’’lf’
Default Value:
0001
Note:
9998 and 9999 are reserved for the block converter A and B if the base address is 9997.
SPA=
SPA?
SPA?
SPA=xxxx
(Same format as
Command
arguments)
Set Statistics
Interval
SSI=
2 bytes
Command or Query.
Sets interval at which statistics are logged. Minimum resolution is 10 m inutes, maximum is 90
minutes in 10 minute intervals.
Default Value:
90
Example:
<1/SSI=90’cr’
>0001/SSI=’cr’’lf’
SSI=
SSI?
SSI?
SSI=xx
(Same format as
Command
arguments)
Software
Revision
N/A
variable length
Query only.
Unit returns the value of the internal software revision installed in the unit, in the form :
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
N/A
SWR?
SWR=Boot:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz
(See Description
of Arguments)
Summary of Contents for MBT-5000
Page 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Page 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Page 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Page 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Page 137: ......
Page 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...