MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Front Panel Operation
Revision 4
5–13
Use the
◄ ►
arrow keys to select
Fault
,
Alarm
, or
Masked
, and then press
ENTER
to return to
the previous menu.
If Power Monitoring is not supported when you select Power alarm masking, the
following message displays:
This Converter Does NOT
Support Power Monitor.
5.2.3.2.1
Out-of-Range Power Supply Masking Using the PS Submenu
Power Supply 1:
Power Supply 2: (◄ ►E)
Use this submenu to configure how out-of-range power supply events are shown on the front
panel
Side A
and
Side B
SUM FAULT
LEDs, and the
Summary Fault Relay.
Select
Power Supply 1
or
Power Supply 2
, and then press
ENTER
.
Alarm Mask: PS
Power Supply X
Power Supply X:
Fault Alarm Masked (◄ ►E)
Use the
◄ ►
arrow keys to select
Fault
,
Alarm
, or
Masked
, and then press
ENTER.
Note the
following:
Selection
State
Fault
Both
SUM FAULT
LEDs are lit and the
Summary Fault Relay
is tripped to the
Fault
position.
Alarm
Both
SUM FAULT
LEDs are lit, but the
Summary Fault Relay
position is not affected
Masked
Neither the
SUM FAULT
LEDs nor the
Summary Fault Relay
are affected.
If all power supplies in the chassis are out of range, then both
SUM FAULT
LEDs are lit (if
able) and the
Summary Fault Relay
is tripped to the
Fault
position.
Power Supply 2 is typically available when the optional Dual Entry Module AC
Power is installed on the optional redundant chassis. Most standalone (i.e.,
single-thread or non-redundant) chassis will not have this AC power option.
For any chassis containing a single power supply, you must set Power Supply
2 as “Masked” to prevent the occurrence of misleading alarms.
Summary of Contents for MBT-5000
Page 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Page 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Page 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Page 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Page 137: ......
Page 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...