MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–12
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
IP Address
IPA=
18 bytes
Command or Query.
Sets the IP address and network prefix for the 10/100 BaseT Ethernet management port, in the
form xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (8-30)
Default Value:
192.168.001.004.24
Example:
IPA=192.168.001.004.24
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=
xx.xxx.xxx.xxx.yy
(See Description of
Arguments)
Gateway
Address
IPG=
15 bytes
Command or Query.
Sets the Gateway IP address for the 10/100 Base Tx Ethernet management port, in the form:
xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx is the IP address
Default Value:
192.168.001.005
Example:
IPG = 192.168.001.005
IPG=
IPG?
IPG*
IPG?
IPG = xxx.xxx.xxx.xxx
Initialize
Statistics
Pointer
ISP=
None
Command only.
Resets internal pointer to allow RNS? Queries to start at the beginning of the stored statistics
log.
Example:
ISP=
ISP=
ISP?
ISP*
N/A
N/A
Local/Remote
State
LRS=
1 byte
Command or Query.
Set Local or Remote
0 = Local, 1=Serial, 2=Ethernet
Default value:
0
Example:
LRS=1
Note:
The customer will always have query access in either mode. Also, the LRS command is
available in all modes as a means of acquiring control. The intent of this command is to limit
changes from being made on multiple interfaces at the same time.
LRS=
LRS?
LRS?
LRS=x
(Same format as
Command
arguments)
Unit MAC
Address
N/A
17 bytes
Query only.
MAC address of the unit, reported in hexadecimal.
Example:
MAC=00-06-B0-00-D2-A7
MAC=
MAC*
MAC?
MAC=xx-xx-xx-xx-xx-
xx
(See Description of
Arguments)
Summary of Contents for MBT-5000
Page 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Page 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Page 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Page 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Page 137: ......
Page 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...