![Comtech EF Data KPA-020IN Installation And Operation Manual Download Page 79](http://html1.mh-extra.com/html/comtech-ef-data/kpa-020in/kpa-020in_installation-and-operation-manual_2648387079.webp)
Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-20
6.9.6 Error
Processing
The following Error Responses may be generated by any command instead of a
confirmation.
General Error
Message:
>DEV?COM CU COMMAND UNRECOGNIZED'cr'' lf']
>DEV?COM IP INVALID PARAMETER'cr'' lf']
>DEV?COM PE PARITY ERROR'cr'' lf']
6.9.7 Configuration
Errors
The following Error Responses may be generated by configuration commands.
Configuration Error Message:
>DEV?COM LO DEVICE IN LOCAL MODE'cr'' lf']
6.9.8 Time-Outs
A time-out should be assumed if there is no response in 1.0 seconds. The station monitor
and control computer should try at least three times. Possible sources of time-outs are
listed in Table 6-2:
Table 6-2. Possible Time-Out Sources
Incorrect Device Address
Faulty Cable
Faulty Connector
I/O fault on remote interface
I/O fault on monitor and control computer
Summary of Contents for KPA-020IN
Page 2: ......
Page 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Page 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Page 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Page 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Page 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...