![Comtech EF Data KPA-020IN Installation And Operation Manual Download Page 71](http://html1.mh-extra.com/html/comtech-ef-data/kpa-020in/kpa-020in_installation-and-operation-manual_2648387071.webp)
Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-12
6.9.4 Status
Commands
Configuration
Status
Configuration Status:
Confirmation:
<DEV/RCS_'cr'
>DEV/RCS_'cr'
ATT_yy.yy'cr'
AMP_nnn'cr'
TX_nnn'cr'
ONL_nnn'cr'
RED_xx_y'cr'
AFR_nnn'cr'
Where:
Attenuator
Amplifier – On/Off
Transmit – On/Off
Online – On/Off
See Note.
Auto Flt Recoverty – On/Off
Notes:
1.
If Redundancy is Off, xx_y = Off,
else if Redundancy is On the xx
field indicates the KPA
designation, either BU (Backup)
01 or 02.
2.
If xx is either 01 or 02 then the y
field indicates the Auto/Manual
status, either A if Auto or M if
manual.
3.
If xx field is BU, the y field
indicates the pripority KPA,
either 1 if KPA #1 is high priority
or 2 if KPA #2 is high priority.
4.
For 1:1 systems prority is
always #1.
Maintenance
Status
Maintenance Status:
Confirmation:
<DEV/RMS_'cr'
>DEV/RMS_'cr'' lf']
V+28_xx.x'cr'
V+12xx.x'cr'
V-12_xx.x'cr'
V+5_x.x'cr'
V–5_x.x'cr'
V+9_1_xx.x'cr'
V+9_2_xx.x'cr'
TEMP_xx'cr'
FPWR_xx.x'cr'
RPWR_xx.x'cr'' lf']
Where:
+28 VDC Supply
+12 VDC Supply
–12 VDC Supply
+5 VDC Supply
–5 VDC Supply
9 VDC Supply #1
9 VDC Supply #2
Temperature
RF Forward Power (dBm)
RF Reflected Power (dBm)
Summary of Contents for KPA-020IN
Page 2: ......
Page 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Page 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Page 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Page 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Page 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...