Ku-Band Solid-State Power Amplifier
Revision 0
Operation
MN/KPA.IOM
4-10
SELECT:
CONFIGURATION
MENU: REDUNDANCY
CONFIGURATION:
SSPA
#1
SSPA-#1--0.00-dB
-ACTIVATE-BACKUP:-NO----
Note:
Window will not display when redundancy is Off.
Gain OFFSET/Forced Backup
- Gain offset: Provides for
±
7.0 dB
offset to be entered for individual KPA’s in redundancy systems for
Gain
Equalization.
Activate
– Provides
ONLINE/OFFLINE
control when manual mode is
selected.
4.2.1.2
SELECT: MONITOR STATUS MENU
---------SELECT---------
--MONITOR-STATUS-MENU---
Monitors and displays the status of:
•
All SSPA Power Supplies
•
SSPA Internal Temperature
•
RF Output Power Level
•
For KPA-040 Only: RF FET (Q1 through Q14)
•
For KPA-020IN/080/100: RF FET (Q1 through Q27)