Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-16
Packed
Configuration
Status
Configuration Status:
Confirmation:
<DEV/PACRCS_'cr'
>DEV/PACRCS_aabcdeffgh'cr'' lf']
Where:
aa = # of 0.25 dB steps in Hex above 0dB
(0 to 120)
b = 1 = Amplifier is On; 0 = Off
c = 1 = TX On; 0 = Off
d = 1 = unit ONLINE; 0 = OFFLINE
e = 1 = Redundancy On; 0 = Redundancy
Off
ff = KPA No. = BU = 01 or 02 ( e = 0, ff =
00)
g = A = Auto Mode; M = Manual Mode
h = 1 = Auto Recovery enabled; 0 if
disabled
Packed
Maintenance
Status
Packed Maint Status:
Confirmation:
<DEV/PACRMS_'cr'
>DEV/PACRMS_aabbccddeeffgghhhiiijjj'cr'' lf']
Where:
aa = + 28 VDC supply, 100mV per count
above 10.0V in Hex
bb = + 12 VDC supply scaled 100 mV per
count in Hex
cc = - 12 VDC supply scaled 100mV per
count in Hex
dd = + 5 VDC supply scaled –100mV per
countin
Hex
ee = - 5 VDC supply scaled –100mV per
count in Hex
ff = + 9 VDC supply #1 scaled 100 mV per
count in Hex
gg = + 9 VDC supply #2 scaled 100mV per
count in Hex
hhh = Signed temperature in degrees C
(-10 to +95)
iii = RF forward power, 0.1 dBm steps
above 20.0 dBm in Hex
jjj = RF reverse power, 0.1 dBm steps
above 15.0 dBm in Hex
Packed FET
Status
KPA-020IN
Packed FET Status:
Confirmation:
<DEV/PACRFS_'cr'
>DEV/PACRFS_aabbccddeeffgghhii’cr'' lf']
Where:
aa = FET1 current in Hex, formular:
FET1 = (aa) mamps
bb = FET2 current in Hex, formular:
FET2 = (aa) mamps
cc = FET3 current in Hex, scaled 100mV
per
count
dd = FET4 current in Hex, scaled
100mV per count
ee = FET5 current in Hex, scaled 100mV
per
count
ff = FET6 current in Hex, scaled 100mV
per
count
gg = FET7 current in Hex, scaled
100mV per count
hh = FET8 current in Hex, scaled
100mV per count
ii = FET9 current in Hex, scaled 100mV
per
count
Summary of Contents for KPA-020IN
Page 2: ......
Page 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Page 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Page 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Page 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Page 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...