Ku-Band Solid-State Power Amplifier
Revision 0
Installation
MN/KPA.IOM
3-2
3.1.1
Redundant Loop Interface, Connector J4
The Redundant Loop Interface connector J4 is a 19-pin circular connector, type
MS3112E14-19S. The pin-out specification is contained in Table 3-2. This connector is
used only in redundant configurations.
Table 3-2. Redundant Loop Interface, Connector J4
Pin #
Description
Pin #
Description
A
Loop In 1
L
Sumflt 2 NO
B
ADDR 2
M
SumFlt 2 Common
C
Loop In 2
N
Local Loop Out
D
Loop Out 2
P
Sumflt 1 NO
E
ADDR Common
R
Sumflt 1 Common
F
ADDR 1
S
Local Sumflt Common
G
Loop Out 1
T
Local Sumflt NO
H
HSB +RX/TX
U
No Connect
J
HSB – RX/TX
V
No Connect
K
Local Loop In
3.1.2
Customer Discrete Control, Connector J5
The Customer Discrete Control connector J5 is a 19-pin circular connector, type
MS3112E14-19S. The pin-out specification is contained in Table 3-3 or Table 3-3a..
Table 3-3. Customer Discrete Control, Connector J5
(Stand-alone or 1:1 System)
Pin #
Signal Name
Description
A
Auto Select
Momentary short to pin F to force entire subsystem to
Auto Mode.
B
BU-1 Command
Momentary short to pin F to force backup of KPA #1.
C
Priority 2 Sel
Not applicable for 1:1 system
D
BU-2 Command
Not applicable for 1:1 system
E
2 Online NO
Not applicable for 1:1 system
F
Remote Common
Control – Remote Common.
G
Online Common
Online Status Common.
H
BU Online NO
Open when Online, all other conditions tied to Pin G.
J
Manual Select
Momentary short to pin F to force entire subsystem to
Manual Mode.
K
1 Online NO
Open when Online, all other conditions tied to Pin G.
L
2 Fault NO
Not applicable for 1:1 system
M
Priority 1 SEL
Momentary short to pin F to set KPA #1 as High priority.
N
Fault Common
Fault Status Common.
P
BU Fault NO
Open when faulted, else tied to Pin N.
R
BU Offline CMD
Momentary short to pin F to force backup KPA Offline.
S
1 Fault NO
Open when faulted, else tied to Pin N.
Summary of Contents for KPA-020IN
Page 2: ......
Page 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Page 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Page 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Page 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Page 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...