Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-14
Utility Status
Utility Status:
Confirmation:
<DEV/RUS_’cr’
>DEV/RUS_’cr’
COMM_aaaaaa'cr'
ADD_xxx'cr'
BR_nnnn'cr'
PAR_nn'cr'
CON_xx'cr'
LCD_xx'cr'' lf']
Where:
RS-232 or RS-485
Address (001 to 255)
Baud Rate (300 to 9600)
Parity (OD or EV)
LCD Contrast (0 to 30)
LCD Brightness (0 to 30)
Alarm Status
KPA-020IN
Alarm Status:
Confitmation:
<DEV/RAS_'cr'
>DEV/RAS_'cr'
+28_xx'cr'
+12_xx'cr'
–12_xx'cr'
+5_xx'cr'
–5_xx'cr'
+9_xx'cr'
TEMP_xx'cr'
FAN1_xx'cr'
FAN2_xx'cr'' lf']
Where:
+28 VDC Fault
+12 VDC Fault
-12 VDC Fault
+ 5 VDC Fault
– 5 VDC Fault
+ 9_xx'cr'
TEMP_xx'cr'
FAN1_xx'cr'
FAN2_xx'cr'' lf']
Alarm Status
KPA-040
Alarm Status:
Confitmation:
<DEV/RAS_'cr'
>DEV/RAS_'cr'
+28_xx'cr'
+12_xx'cr'
–12_xx'cr'
+5_xx'cr'
–5_xx'cr'
+9_xx'cr'
TEMP_xx'cr'
SHTD_xx'cr'
FAN1_xx'cr'
FAN2_xx'cr'
PROC_xx’cr’' lf']
Where: xx = OK or FT
+28 VDC Fault
+12 VDC Fault
-12 VDC Fault
+ 5 VDC Fault
– 5 VDC Fault
+9 VDC Fault
TEMP_xx'cr'
Over Temperature Shutdown
FAN1 Fault
FAN2 Fault
Processor Fault
Note: A temperature fault is indicated if
the unit is
≤
-12
°
C or
≥
+80
°
C. This
creates a summary fault and will cause
the unit to mute itself and switchover to
the back-up unit. However, the 9V
supply to the FET transistors will
remain on until the unit reaches the
thermal shutdown temperature of
≥
89
°
C. For protection reasons, the unit
will shutdown the 9V supply to the
power transistors at temperatures
≥
+89
°
C.
Summary of Contents for KPA-020IN
Page 2: ......
Page 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Page 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Page 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Page 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Page 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...