- 18 -
turned off. But the “Auto-controlled by temperature” feature
is applied only when command 20 is set.
Method:
The user sends following SMS message in order to:
Set temperature to switch on/off the output:
#159#Mode#LowTemp#HighTemp#
Mode is the control selection:
For coldness, mode=0. For warmness, mode=1.
Temp means temperature value, the range is –10C
to 49C.
Temperature unit is degree Celsius.
Example 1:
set commands: #159#0#20#30# when the
environmental temperature is 35 degrees (above the
limitation of 30 degrees in the command) the socket out-
put will be on, cooling apparatus starts working; when
the environmental temperature is 18 degrees (below the
limitation of 20 degrees in the command), the socket out-
put will be off, heating apparatus stops working.
Example 2:
set commands: #159#1#10#20# when
the environmental temperature is 5 degrees (below
the limitation of 10 degrees in the command), the
socket output will be on, heating apparatus starts
working; when the environmental temperature is 24
degrees (above the limitation of 20 degrees in the
command), the socket output will be off, cooling appa-
ratus stops working.
3.5.3 Disable auto-controlled by temperature
Method:
The user sends following SMS message in order to:
Disable auto-control the output by temperature:
#159#00# (22)
Successful SMS reply
Status ON/OFF
Delay control: function ON/OFF
Schedule control: function ON/FF
Temp control: OFF
Temp: 25C
Mode: Heating/Cooling
Range: Low Temp-HighTemp