3.6.2 Temperature rapid changing alarm
Description:
A time period value and temperature changing value can
be preset. If the surrounding temperature changes to the
preset value within the preset time period, a SMS alert
message will be auto-sent to master user’s mobile phone.
This feature depends on the temperature sensor and
settings.
Method:
The user sends following SMS message in order to:
Enable rapid changing temperature alarm:
#160#1#
Set time period and temperature changing value:
#160#Temp#Time#
Disable rapid changing temperature alarm:
#160#0#
Temp
: The values lies in the range from 1-60
centigrade degree.
Time
: The values lies in the range from 1-30 minutes.
Please set up the temp and time value when you use
the function at first time.
The sensor will detect the temperature every 6
second. Once the temperature changes rapidly, the
socket will auto send the SMS alerts to master user
every minute and it “beep” until you disable it.
Successful SMS reply
Temperature rapid changing: function ON
Delta: 4C
Time: 2minutes
3.7 SMS notification upon the socket output changing
Description:
GSM158
will default notify the user when the socket output
changing. A SMS notification will be sent. The Master user
can enable/disable this SMS notification.
- 20 -