- 26 -
CHAPTER 6
MAIN TECHNICAL PARAMETERS
• Input power socket
:
110-250V/50Hz,CEE 7/7 Schuko plug
• Output power socket relay:
110-250V/50Hz,230V/30A(30s),
15A long term
• Store temperature:
-10°C - +49°C
• Relative humidity:
-20°C - +60°C
• Relative humidity:
10-90% without condensation
• Data interface:
GSM SIM 1.8V/3.0V socket
• External temperature sensor:
-10°C - +50°C
• GSM working band:
DCS1800, PCS1900, GSM850, EGSM900
CHAPTER 7
SMS COMMANDS LIST
CATEGORY
FUNCTION
Add a Master number
to the socket
#99#phone#code#
Change master password
#04#oldpassword#newpassword#
Change the Master
user's number
#14#Newphone#oldphone#code#
Add a Additional number
#06#FamilyNumber#code#
Add several Additional
numbers
#06#Additional Number1#...
#Additional Number4#code#
Delete a Additional number
#113#FamilyNumber#code#
Delete several Additional
numbers simultaneously
#113#Additional Number1#...
#Additional Number4#code#
Delete all Additional numbers
#113#code#
Switch on the socket output
(manually)
#01#
Switch off the socket output
(manually)
#00#
Enable switching on/off
the output by calling
#18#1#
Disable switching on/off
the output by calling
(Default)
#18#0#
Switch on the auxiliary output
#11#1#
Switch off the auxiliary output
#11#0#
Delay switching on
the output after a
certain minutes
#138#1#Minutes#
Delay switching off
the output after a
certain minutes
#138#0#Minutes#
Disable the delay control
#138#0#0#
Set time period to switch
on and off the output
#128#WorkDay#StartTime#EndTime#
Set temperature range
to switch on/off the output
#159#mode#MinTemp#MaxTemp#
Disable auto-control
the output by temperature
#159#00#
Enable auto-command
the output by temperature
#159#01#
Set time period to
switch on the output
#128#WorkDay#StartTime#0#
Set time period to
switch off the output
#128#WorkDay#0#EndTime#
Disable timing
switch on the output
#128#00#
Set limit of temperature
#170#0#LowTemp#HighTemp#
Set limit of temperature
#170#1#LowTemp#HighTemp#
Disable the over-temperature
alarm
#170#00#
Enable the over temperature
alarm
#170#01#
Disable the temperature
rapid changing alarm
#160#0#
Set time period and
temperature changing value
#160#Temp#Time#
Enable the temperature
rapid changing alarm
#160#1#
No SMS notification upon
the power supply changing
#12#0#
SMS notification upon
the power supply
changing (Default)
#12#1#
Enable timing switch
on the output
#128#01#
COMMAND
NO.
Define
the users
Switching
on/off
output
Delay
control
Schedule
control
Temperature
control
Over
temperature
control
Temperature
rapid
changing
alarm
SMS
Notification
"Beep"
warning
tone
Check
Status
Reset to
factory
settings
Switching
on/off
auxiliary output
#19#1#
Enable the "Beep"
warning tone (Default)
#159#
Check "Temperature contorl"
parameters
#160#
Check "Temperature rapid-
changing" parameters
#170#
Check "over-Temperature alarm"
parameters
#08#
Reset the socket
#19#0#
Disable the "Beep"
warning tone
#07#
Check socket
operating status
#000#
Check socket
output status
#06#
Check auxiliary
output status
#138#
Check "Delayed switch
on/off the socket"
parameters
#128#
Check "Timed switch
on the socket" parameters
#130#1#
SMS notification upon
the socket output
changing (Default)
#130#0#
No SMS notification upon
the socket output changing
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47