WorkDay
: one digit, the values lie in the range of “0”
to “8”. The following table contains the descriptions of
each value.
0
- Monday to Friday
1
- Monday
2
- Tuesday
3
- Wednesday
4
- Thursday
5
- Friday
6
- Saturday
7
- Sunday
8
- Everyday
StartTime and EndTime
: consists of 4 digits (hh:mm)
and works on a 24 hour clock. If the EndTime is later
than StartTime, the period is in the same day. If the
EndTime is earlier than StartTime, the EndTime is on
next day.
The socket output will switch on at the StartTime and
cut off at the EndTime.
For example:
#128#0#0000#2130#
This means the socket will open on 00:00 and close on
21:30 every Monday to Friday.
#128#0#2130#0000#
This means the socket will open on 21:30 and close on next
day 00:00 every Monday to Friday.
#128#1#0900#0#
This means the socket will open on 09:00 every Monday.
#128#5#0#1800#
This means the socket will close on 18:00 every Friday.
Successful SMS reply
Temp control: function ON/OFF
Delay control: function ON/OFF
Schedule control: function ON
Monday to Friday, 00:00-21:30
3.4.3 Disable timing switching on the output
Method:
The user sends following SMS message in order to:
Disable timing switch on/off the output:
#128#00#