Troubleshooting and Diagnostics
Compaq ES40CSLP Rackmount System Installation/User/Service Guide 6–59
6.7.6.4 fru
The fru command is similar to the SRM show fru command. It is used to access information in
the shared RAM FRU EEROM locations based on the logical device name you enter at the
dev> prompt. The logical device names are:
Name
Meaning
cpu0, cpu1, cpu2, cpu3
CPUs
dimm {0-31}
Memory DIMMs
mmb {0, 1, 2, 3}
Memory motherboards
sys
System board
pci
PCI backplane
The following example shows information on the CPU0 module.
RMC>fru
dev>cpu0
Slot
Part#
Rev
Serial#
Events Logged
SDD
TDD
0
25241111
A1
KA426C0457
00
00
RMC>
6.8 Option Card Problems
Option card problems can include problems related to network options and PCI options.
Network Problems
Network problems can vary, depending on the type of network option card that you have
installed. See the option card documentation for information on troubleshooting network
problems. Make sure you have correctly set the network type for the network interface card.
PCI Parity Errors
Some PCI devices do not implement PCI parity, and some have a parity-generating scheme that
may not comply with the PCI Specification. In such cases, the device functions properly as
long as parity is not checked.
You can turn off parity checking so that false PCI parity errors do not result in machine check
errors. When you disable PCI parity, no parity checking is implemented for any PCI device.
For Tru64 UNIX and OpenVMS systems, use the set pci_parity off command from the SRM
console.
Summary of Contents for ES40CSLP
Page 10: ...This is some white text...
Page 14: ...This is some white text...
Page 46: ...This is some white text...
Page 80: ...This is some white text...
Page 98: ...This is some white text...
Page 126: ...This is some white text...
Page 188: ...This is some white text...
Page 190: ...This is some white text...