Installing the Optional Hot-Plug Drive Cage
Installing the optional 2 x 1-inch drive cage allows you use up to two
additional 1-inch hot-plug Wide Ultra2 or Ultra3 drives in your
ProLiant CL380 server. The standard Integrated Smart Array Controller in
your server supports the drive cage and additional hot-plug drives. Figure 4-66
illustrates a ProLiant CL380 with the optional drives installed, with the
corresponding SCSI IDs shown. Please refer to Appendix H, “SCSI ID
Configurations” for more information on SCSI IDs.
NOTE:
When combining Ultra2 and Ultra3 hard drives, all of the drives are limited to
response times no faster than the maximum burst rate of up to 80 MB/s on the Ultra2
SCSI bus, or the transfer rate of the slowest device in the array.
NOTE:
Refer to the previous sections on Removable media devices, in this chapter, to
assist in this process.
1
9
10 11
12
13 14
0
3
2
3
2
1
0
Figure 4-66. ProLiant CL380 with optional drive cages and SCSI IDs shown
1.
Remove the node from the system.
NOTE:
For information on removing a server node from the system, see “Removing a
Server Node” section earlier in this chapter.
2.
Remove the removable media trays from the node.
NOTE:
For information on removing the removable media trays from the node, see
“Removing the Removable Media Tray” section earlier in this chapter.