background image

 

 

  

 

Your new SCC 5320 

You have received a new SCC 5320 (Supply & Communications Computer) loaded with 
relevant software version and the latest database backup we had on our server. This means 
that if you have made any changes in the system after this database backup was made it will 
be lost. However if your current SCC is working you can take a database backup and install to 
your new SCC 5320.  

 
Please read the whole instruction before installing your new SCC 5320.

 

 

Database Backup 

If your old SCC works we recommend you to take a new database backup before changing SCC. This can 
only be done if you have a SCD touchscreen display installed.   

1.

 

In Service Window, press the Backup Database Button and log in (password: star). 

2.

 

Connect the USB Memory Stick to the USB port on the LEVEL SCC. 

3.

 

Select the removable media you want to use for the backup in the “Backup to Media” drop down 

list. 

4.

 

Press the Backup button. 

The “Comments” window is opened

5.

 

You can now enter any comments you might have to the backup. The text will be stored in the 
backup file and can be read when using this backup to restore the database. 

6.

 

Press the OK Button and the backup will start. 
- A dialogue window displays if the backup is successful. 

7.

 

The name of the backup file is displayed in the field “FileName”

Press Exit to close backup procedure. 

8.

 

Disconnect the USB Memory Stick from the USB port. 

 
For more information check your service manual

 

Regular database backup 

We recommend to make regular database backups to prevent you from losing settings if the system goes 
down and you need a new SCC. This is recommended to add in your maintenance plan 

so it’s done at least 

once every 6 months.  

 

Send copy of database for storage 

In order for us to give you quick and easy support in the future, we recommend you to send your backups 
to us on a regular basis, so that we can store it for you.  

Use this site to send backup 

https://emerson.sendthisfile.com

 and add 

[email protected]

 as 

recipient email. 

 

Problem with installation 

If you have any problem or questions please contact our service department at 

[email protected]

 and we will help you. 

Summary of Contents for Rosemount TankRadar SCC 5320

Page 1: ...y comments you might have to the backup The text will be stored in the backup file and can be read when using this backup to restore the database 6 Press the OK Button and the backup will start A dialogue window displays if the backup is successful 7 The name of the backup file is displayed in the field FileName Press Exit to close backup procedure 8 Disconnect the USB Memory Stick from the USB po...

Page 2: ...ect them again 3 Remove the old SCC and replace it by the new one mounted on a plate 4 Connect the black four port cable between the SCC 5320 and the green com port adapter board 5 Connect all wires and connectors in the corresponding positions and wire positions as noted in section Hardware Connections below For example the serial cable connected to COM3 on the old SCC shall be connected to COM3 ...

Page 3: ... cable to the SCD panel must be connected to the SCC through the supplied DVI to VGA adapter Note SSD disk should always be placed in the SSD 0 slot below the DVI port COM1 SCD VGA through a DVI adapter not in the picture Main Network SCD USB 24V DC Main Main Optional Optional COM2 COM3 COM6 Extra Network for future functions USB memory stick Four Port Cable SSD 0 Slot ...

Page 4: ...dapter DATA 1 4 DATA 2 5 GND 3 3 I e the wires must be connected to a different position compared to the old adapter COM3 and COM4 in RS 422 mode Signal Position on old adapter Position on new adapter Tx 1 1 Tx 2 2 GND 3 3 Rx 4 4 Rx 5 5 I e use the same position on the new adapter as on the old adapter COM5 and COM6 RS 232 Signal Position on old adapter Position on new adapter CTS 1 1 TxD 2 2 GND ...