G8-TEL / G3-TEL
Auto-dialler mode
2.0/0817
15
Activate dialling sequence
The different dialling sequences are activated via inputs to which e.g. a time switch can be connected.
For the inputs, a dialling simulation has to be configured with the following code:
Enter “XX9T99” and the number of the dialling sequence (e.g. “XX9T992” to activate dialling
“sequence 2”).
Configuration CCT 800
Inputs > Dial via Input > Input initiates dialling
Right-click on the desired input and select the option “Add input initiates dialling”.
Inputs > Dial via Input > Input initiates dialling >
folder
input #
In the drop-down list
Subscriber 1
, select the telephone interface for which the dialling sequence
shall be switched over.
In the drop-down list
Dial / Key
next to the desired input level (e.g. “Short”), enter the respective
code.
Input initiates dialling window in CCT 800
In the example above (screenshot), one input triggers the switch-over of the dialling sequences “1” and
“2” for the subscriber “1” (telephone interface):
Level input:
Break
(dialling sequence “1” is active)
Level input:
Short
(dialling sequence “2” is active)
NOTES: Existing call
With the prefix “XX“, an existing conversation (set up by dialling the interface call number) is can-
celled before switching the dialling sequence. Otherwise, the sequence would not be changed.
“XX” has no effect on an existing call request. The call remains and is transferred to the new dial-
ling sequence.
ATTENTION: Simultaneous dialled codes
Make sure that two inputs cannot dial a code at the same time. This could happen e.g. if codes for
“short” and “open” are configured for several inputs. If one input closes and the other opens at the
same time, it cannot be guaranteed if the “open” code or the “short” code was dialled first, because
always the code dialled last becomes effective.