background image

G8-TEL / G3-TEL

PABX mode

2.0/0817

25

In the field 

Dial prefix

, enter, if required, a number that is automatically pre-dialled (max. 8 digits),

e.g. an exchange number for dialling out or for selecting a certain provider. Admissible characters:
“0” to “9”, “*”, “#” or “P” (for one second pause)

In the field 

DTMF decoding time [ms]

, enter, if required, the DTMF decoding time in milliseconds

(“60” by default).

In the field

 DTMF tone period [ms]

, enter, if required, the tone duration of the DTMF tone in milli-

seconds (“80” by default).

In the field 

DTMF gap period [ms]

, enter, if required, the pause between the DTMF tones in milli-

seconds (“70” by default).

In the drop-down list 

DTMF Gain

, select the gain of the DTMF tone. Options: “Default”, “+6 dB” and

“-6 dB”

Call request in PABX mode

The dialling sequences and telephone numbers have to be configured as described at 

“Activate di-

alling sequence” on page 15

.

The telephone interface has to be configured as control desk at 

Subscriber > Control Desks

.

For the calling station, a call request has to be configured to the telephone interface at 

Subscriber

> Call Request

.

For a calling input, an input message has to be configured to the telephone interface at 

Inputs >

Input message

If a calm-down message shall be put out at the calling station after initiation of a call request, an ap-
propriate configuration in CCT 800 is required (

see “Calm-down message for call requests” on

page 18

)

Phone call by dialling manually

To set up a phone call by dialling the telephone interface manually, no particular configuration in CCT
800 is required. At the Intercom station, simply the call number of the telephone interface and the tele-
phone have to be dialled. 

NOTE: Telephone numbers and Sequences

Entries made in the columns 

Telephone numbers 

and 

Sequences

 (in PABX mode) only have an

effect on call requests or input messages 

(

see below

).

NOTE: Further information

For further information on call requests, see manual “

Intercom Server Configuration

”.

ATTENTION: Input messages

If the indication of input messages via buzzer is deactivated, no call

 

is initiated to the telephone

(

Inputs > Input message > 

tab

 Call types

).

NOTE: Dialling the telephone interface manually

To simplify the dialling of the telephone interface, the following options are available:

If only certain Intercom stations shall use the telephone function, the number of the telephone inter-
face has to be defined as direct dialling for the desired button at 

Subscriber > Direct Dialling

.

If all Intercom stations shall use the telephone function, the best way is to change the call number of 
the telephone interface to the desired digit or code at

 Subscribers > Naming

. If e.g. the call number 

of the telephone interface is changed to “7”, all Intercom stations can use the telephone function by 
pre-dialling 

7

.

Summary of Contents for C-G3-TEL

Page 1: ...G8 TEL G3 TEL MANUAL VERSION 2 0 0817 PRODUCT MANUAL ENGLISH...

Page 2: ...event of problems contact your equipment supplier in the first instance Before exchanging cards ESD precautions must be observed Installation reference for Germany The G3 TEL G8 TEL card may be connec...

Page 3: ...from the telephone to the Intercom system 13 Configure auto dialler mode 13 Speech storage 17 Pre recorded audio for speech storage 20 Recording messages at the Intercom station 20 PABX mode 22 Outgoi...

Page 4: ...n By dialling the telephone interface it is possible to dial into the Intercom Server from any telephone within the telephone network By doing this Intercom functions can be carried out with the DTMF...

Page 5: ...connection RJ11 Power supply via Intercom Server Emergency power consumption 0 1 Ah h Operating temperature range 0 C to 50 C 32 F to 122 F Storage temperature range 30 C to 60 C 22 F to 140 F Relativ...

Page 6: ...nnection to the main processor e g during initialising or reset LED flashes fast card is inserted in the wrong slot or speech messages are loaded Status telephone line LINE LED is permanently on on ho...

Page 7: ...m Server GE 800 the connection board G8A TEL has to be used included in extent of supply Pin assignment connection board G8A TEL G3 TEL The G3 TEL is designed for the Intercom Server GE 300 The card c...

Page 8: ...through after a configurable time Display the dialled telephone number The telephone number dialled in PABX mode is shown on the display In addition a cursor shows if the dialling process has been co...

Page 9: ...all number several times in a dialling sequence Example Call numbers 1 Guard 1 2 Guard 2 3 SIP mobile phone 1 4 SIP mobile phone 2 In the daytime Dialling sequence 1 is selected by a time switch When...

Page 10: ...u will be immediately connected to an emergency station This message is repeated until the call is taken over via the telephone Messages at the telephone Location message The telephone receives the lo...

Page 11: ...rsation can be set up or other functions can be carried out in the Intercom Server If the telephone is only hanged up without pressing the connection is automatically disconnect ed after approx 6 seco...

Page 12: ...on Telephone within the public telephone net Initiate a call Calm down message Telephone is ringing Going off hook Location message Enter password Individual message optional Call Conversation End Can...

Page 13: ...ing the conversation at the telephone Repeated speech messages can be interrupted with see also Individual messages on page 19 However each message has to be listened to at least once Cancel conversat...

Page 14: ...alled max 8 digits e g an exchange number for dialling out or for selecting a certain provider Admissible characters 0 to 9 or P for one second pause In the field DTMF decoding time ms enter if requir...

Page 15: ...ve code Input initiates dialling window in CCT 800 In the example above screenshot one input triggers the switch over of the dialling sequences 1 and 2 for the subscriber 1 telephone interface Level i...

Page 16: ...e will be transferred via the telephone interface as Active 2 Standard The call type will be grouped to none of the above listed call types Initiate call Call via dialling interface At the Intercom st...

Page 17: ...0 Ruf Call Appel 11 Rufe Calls Appels 12 Notruf Emergency call Appel de secours 13 Notrufe Emergency calls Appels de secours 14 Bitte bewahren Sie Ruhe Sie werden sofort zu einem Not rufservice durchg...

Page 18: ...al data on page 5 For an overview of switching on several speech messages in auto dialler mode see Switch on speech messages on page 10 and Examples for the call procedure on page 12 NOTES Calm down m...

Page 19: ...f the Intercom station to or from which the call is initiated If the message shall be valid for all Intercom stations enter In the drop down list Call Type select the event or the type of the respecti...

Page 20: ...tion Speech storage messages see Standard speech messages on page 17 can also be recorded at the Intercom station The recording can be performed in normal operation in order to test the speech stor ag...

Page 21: ...essage and release T when the message is complete Press 0 to listen to the recording Press 1 to save the recorded message Further options Press X to cancel without saving Press 2 to load a recorded me...

Page 22: ...t is possible to define several phone numbers per telephone interface via the PA function see Phone call by direct outward dialling on page 26 which can be dialled directly at the Intercom sta tion wi...

Page 23: ...ll from the telephone to the Intercom system Initiate call A call in PABX is initiated in the same way as in auto dialler mode see page 13 Cancel conversation A conversation in PABX mode is cancelled...

Page 24: ...f the sequence hast to be dialled if the call was not accepted In the drop down list Dial tone telephone select the dial tone for the telephone or deactivate it Options None British 440Hz and Telephon...

Page 25: ...an ap propriate configuration in CCT 800 is required see Calm down message for call requests on page 18 Phone call by dialling manually To set up a phone call by dialling the telephone interface manua...

Page 26: ...f all required numbers are entered click on Accept The entered numbers are indicated in the field PA Numbers PA numbers in CCT 800 After dialling at the telephone outgoing phone call For outgoing phon...

Page 27: ...ring the last digit of the respective telephone number the after dial mode is switched automatically from DTMF dialling to Intercom dialling I e it is possible to after dial into the Intercom system V...

Page 28: ...istening to a channel and talking into a channel at the telephone 7T predefined conference Initiating a 7T conference at the telephone 8T conference On the telephone a conference can be initiated in t...

Page 29: ...g function at the telephone at PABX mode an appropriate configuration in CCT 800 is required see After dialling at the telephone outgoing phone call on page 26 ATTENTION Button 7 When using the teleph...

Page 30: ...Technical support G8 TEL G3 TEL 30 2 0 0817 Technical support For more information about our products and services visit www commend com...