5.5.5 Isolators
Vedo 10
x: from 1 to 4 /
Vedo 34
x: from 1 to 8 /
Vedo 68
x: from 1 to 16
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.9.x.2
Tamper areas
At least one selected area
1.1.1.9.x.3
Technical areas
At least one selected area
1.1.1.9.x.4
Tamper cycles
Unlimited
1.1.1.9.x.5
Technical cycles
Unlimited
1.1.1.9.x.7
Unlimited tamper cycles
Selected
1.1.1.9.x.8
Unlimited technical cycles
Selected
1.1.1.9.x.11
Send digital
communications
Selected
1.1.1.9.x.13
Tamper enabled
Selected
5.5.6 Radio expansion
Vedo 10
x: from 1 to 1 /
Vedo 34
x: from 1 to 2 /
Vedo 68
x: from 1 to 3
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.10.x.2
Tamper areas
At least one selected area
1.1.1.10.x.3
Technical areas
At least one selected area
1.1.1.10.x.4
Tamper cycles
Unlimited
1.1.1.10.x.5
Technical cycles
Unlimited
1.1.1.10.x.7
Unlimited tamper cycles
Selected
1.1.1.10.x.8
Unlimited technical cycles
Selected
1.1.1.10.x.11
Send digital communication
Selected
5.5.7 Radio outputs
Vedo 10
x: from 1 to 16 /
Vedo 34
x: from 1 to 32 /
Vedo 68
x: from 1 to 48
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.11.x.7
Siren on time out (not
active)
**
1.1.1.11.x.8
Siren sound for on (not
active)
**
1.1.1.11.x.13
Cycle Outputs
**
1.1.1.11.x.14
Unlimited Cycle Outputs
**
1.1.1.11.x.15
Output type
*** Monostable
1.1.1.11.x.17
OFF Time
**
1.1.1.11.x.19
ON Time
**
1.1.1.11.x.20
System status areas
At least one selected area
1.1.1.11.x.21
Tamper and technical areas
At least one selected area
1.1.1.11.x.22
Sabotage cycles
Unlimited
1.1.1.11.x.23
Technical cycles
Unlimited
1.1.1.11.x.24
Monitoring time
Maximum 20 minutes
1.1.1.11.x.25
Unlimited sabotage cycles
Selected
1.1.1.11.x.26
Unlimited technical cycles
Selected
1.1.1.11.x.31
Disable battery check
Selected
** The total activation time of a siren must not exceed that prescribed by local regulations.
*** These apply only to sirens
RADIO OUTPUT EVENTS
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.11.x.27.y.1 Event
* Alarms/S Motion sensor
jamming fault
1.1.1.11.x.27.y.2 Polarity
* Direct
1.1.1.11.x.27.y.3 And/or
* OR
* These apply only to sirens
RADIO OUTPUT CONFIGURATION
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.11.x.28.1.1
Timer in And
* No timer
1.1.1.11.x.28.1.2
Timer in Or
* No timer
1.1.1.11.x.28.1.7
Events logic
* OR
1.1.1.11.x.28.1.12
Output activation only with
system activated
Selected if connected to a siren
* These apply only to sirens
5.5.8 Radio controls
Vedo 10
x: from 1 to 8 /
Vedo 34
x: from 1 to 32 /
Vedo 68
x: from 1 to 50
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.12.x.3
Areas
At least one selected area
1.1.1.12.x.5
Unlimited fault cycles
Selected
1.1.1.12.x.7
Fault cycles
Unlimited
1.1.1.12.x.14
Send digital
communications
Selected
1.1.1.12.x.19
Forced activation
Deselected
5.5.9 Radio zones
Vedo 10
x: from 1 to 16 /
Vedo 34
x: from 1 to 64 /
Vedo 68
x: from 1 to 96
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.13.x.3
Monitoring
Maximum 20 minutes
1.1.1.13.x.16
Unlimited fault cycles
Selected
1.1.1.13.x.18
Fault cycles
Unlimited
1.1.1.13.x.20
Tamper enable
Selected
RADIO SUBZONE PARAMETERS
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.13.x.21.1.3
Areas
At least one selected area
1.1.1.13.x.21.1.4
Alarm cycles
Unlimited
1.1.1.13.x.21.1.22
Can be self-disabled (alarm
only)
Deselected
1.1.1.13.x.21.1.23
Can be self-disabled with
reset (alarm only)
Deselected
1.1.1.13.x.21.1.30
Unlimited alarm cycles
Selected
1.1.1.13.x.21.1.45
Send digital com
Selected
5.5.10 Wired zones
Vedo 10
x: from 1 to 16 /
Vedo 34
x: from 1 to 95 /
Vedo 68
x: from 1 to 133
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.14.x.13
Balancing
All alarm, fault and command zones
must be set to double or triple balance
or double with EOL. The sabotage
zones must be set to single or double
or triple or triple with jamming or double
with EOL.
1.1.1.14.x.14
Unlimited fault cycles
Selected
1.1.1.14.x.15
Fault cycles
Unlimited
* If triple balance is not used for all the sensors, three inputs of the control panel must be
programmed to signal the following events:
- Detector fault
- Anti-robbery device fault, if robbery zone present
- Siren fault
In order to guarantee compliance with Standards EN50131-1 and EN50131-3:
In order to guarantee compliance with Standards EN50131-1 and EN50131-3, a siren
sabotage zone must be provided.
SUBZONE PARAMETERS
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.14.x.15.y.3
Areas
At least one selected area
1.1.1.14.x.15.y.4
Alarm cycles
Unlimited
1.1.1.14.x.15.y.22
Can be self-disabled (alarm
only)
Deselected
1.1.1.14.x.15.y.23
Can be self-disabled with
reset (alarm only)
Deselected
1.1.1.14.x.15.y.30
Unlimited alarm cycles
Selected
1.1.1.14.x.15.y.45
Send digital com
Selected
5.5.11 Areas
Vedo 10
x: from 1 to 2 /
Vedo 34
x: from 1 to 8 /
Vedo 68
x: from 1 to 8
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.16.x.4
Entry 1 time
Max 45 seconds
1.1.1.16.x.5
Entry 2 time
Max 45 seconds
1.1.1.16.x.8
Pre-alert time
Other than 0
1.1.1.16.x.10
Pre-alarm time
0
1.1.1.16.x.15
Report pre-alert
Selected
5.5.12 Wired outputs
Vedo 10
x: from 1 to 7 /
Vedo 34
x: from 1 to 75 /
Vedo 68
x: from 1 to 115
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.17.x.3
Output type
* Monostable
1.1.1.17.x.5
Unlimited cycles
Deselected
1.1.1.17.x.6
ON time scale
**
1.1.1.17.x.7
ON Time
**
1.1.1.17.x.8
OFF TIME:
**
1.1.1.17.x.10
Cycles
**
* These apply only to outputs connected to sirens
** The total activation time of a siren must not exceed that prescribed by local regulations.
WIRED OUTPUT EVENTS
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.17.x.11.y.1
Event
* Alarms/S Motion sensor
jamming fault
1.1.1.17.x.11.y.2
Polarity
* Direct
1.1.1.17.x.11.y.3
And/or
* OR
* These apply only to outputs connected to sirens