Note that the standard speed of the bus for VEDO control
panels is 38400 Baud.
The plastic housing allows flush mounting in residential series
boxes or on DIN rails.
SETTING SPEED ON THE BUS
MOUNTING
BAUD
DIP5
DIP6
9600
OFF
OFF
38400
OFF
ON
57600
ON
OFF
115200
ON
ON
Name Function
JP1
If activated, enables 485 bus input terminal resistor*
JP2
If activated, enables 485 bus output terminal resistor*
LED MEANINGS
TAMPER CONTACT CONNECTION
Name Function
DL1
Flashing slowly: no data transfer over bus at the speed set using
the dip switch.
Flashing quickly: data transfer over bus in progress.
DL2
Off: the peripheral is communicating correctly;
Very slow flashing: (approx. 3 seconds) no data package on the
BUS.
To access dip switch S1 and jumpers JP1 and JP2, you must
remove the plastic casing at the top.
DEFAULT
The
24H
terminal needs the Tamper contact to be connected in
single balanced configuration. A resistance of
1.8KΩ
, in series
with the contact, is required.
ALARMS
SINGLE BALANCED
To guarantee system certification, the isolator must be positioned
in boxes protected by an anti-opening switch, or in the control
panel housing. The 24h input must be connected to a balanced line.
CONFIGURATION JUMPERS
The device address
must be unique and can only be
programmed using dip switches.
ADDRESSING
No.
DIP1
DIP2
DIP3
DIP4
1
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
4
ON
ON
OFF
OFF
5
OFF
OFF
ON
OFF
6
ON
OFF
ON
OFF
7
OFF
ON
ON
OFF
8
ON
ON
ON
OFF
9
OFF
OFF
OFF
ON
10
ON
OFF
OFF
ON
11
OFF
ON
OFF
ON
12
ON
ON
OFF
ON
13
OFF
OFF
ON
ON
14
ON
OFF
ON
ON
15
OFF
ON
ON
ON
16
ON
ON
ON
ON