![Comelit VEDO10 Technical Manual Download Page 16](http://html1.mh-extra.com/html/comelit/vedo10/vedo10_technical-manual_2640394016.webp)
16
DL5
P1
P2
P3
DL1 DL2 DL3 DL4
1
2
3
Times for detecting and presenting
faults
No GSM/GPRS coverage:
120 sec.
SIM fault:
20 sec.
antenna disconnected:
45 sec.
Level of output signals and/or
sensitivity of input signals
Minimum level DTMF tones at
input:
36mVeff - 28.8dbV 100mVpp
Level DTMF tones at output:
low
freq 9dBm / high freq 11dBm
Safety signals level supplied
ATS2-I0 no information protection
ATS2-S1 protection against
substitution
Sharing of transmission connections
GSM: GSM850, EGSM900,
DCS1800, PCS 1900
Class 4 (2W) for GSM850 / EGSM900
Class 1 (1W) for DCS1800 / PCS1900
3.4.3 GSM communication expansion module (Art.
VEDOGSM)
GSM MODULE FUNCTIONS
Art. VEDOGSM complies with standards EN50131-1,
EN50136-1-1, EN50136-2-1, EN 61000-6-3 (2007) + A1 (2011)
The device is immune to the disturbances governed by
standard EN 50130-4.
Emission standards with which the device complies: EN61000-
6-3, EN50130-4, EN301489-1, EN301489-3, EN301489-7.
The GSM communication expansion module Art. VEDOGSM
allows telephone calls, SMS, MMS and e-mails to be sent on
the data network. Combined with the voice message card Art.
VEDOVOICE, it allows the remote management of the control
panel by a voice communicator.
• GSM850, EGSM900, DCS1800, PCS 1900
• GSM/GPRS channel support
• Main or reserve telephone dialler
• Indication of alarms/malfunctions/sabotage/events via SMS
• Customisable SMS messages
• Control panel status interrogation via SMS
• Checking residual credit of the prepaid SIM
• Transmission of Voice Messages via GSM
• Transmission of Contact ID via GSM
• Event transmission in Contact ID format
• Event transmission by email with images
• Event transmission by MMS
1.
Antenna connector
2.
SIM housing
3.
Module connector position
Holes for fixing the VEDOGSM module to the control panel card Art.
PCBVEDO10, Art. PCBVEDO34, Art. PCBVEDO68
TECHNICAL SPECIFICATIONS
Features Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
70 x 48 x 29 mm
(without antenna)
Weight
26g without antenna
44g with antenna
Consumption (min./max.)
27mA in Idle
47mA in communication
Operating temperature and
Operating humidity
-10° / + 55° with warm dry air
-10° / + 40° C with max + 93% RH
(not condensed)
Certifiable safety grade
2 according to EN50131-1*
Environmental class
II according to EN50131-1
* Respecting any indications for configuration and installation
SPECIFICATIONS ACCORDING TO STANDARD EN50136-2-1
FITTING THE GSM MODULE
Insert the plastic spacers in the relevant holes. Then, taking care
to plug the module connector into the control panel connector
designated MOD5 correctly (see page 13), apply sufficient
pressure to engage the spacers in the GSM expansion card
and plug the connector in almost completely.
Make sure the card on which you intend to fit the module is
not connected to the power supply.
IMPORTANT: any operation involving the assembly or
disassembly of expansion modules must be performed
with all input power (from power supply unit or battery)
OFF, in order to avoid permanently damaging the
expansion module you intend to add or remove, as well as
the control panel card.
Once the module has been fitted correctly, connect the antenna
that you intend to use by tightening the connector on the cable
to the gold-coloured connector on the GSM module.
Before using the module, it must be enabled with the
Safe Manager software. If the module is enabled but not
connected, a fault will be generated.
MEANING OF THE LEDS ON THE IP GSM MODULE
CONFIGURATION JUMPERS
Name Function
DL1
Red LED:
GSM communication. Flashes when a transfer via
the GSM or GPRS network is in progress, e.g. during receipt
of an SMS or during registration with the network at the time of
initialisation.
DL2
red LED steadily lit
: during reset, during initial configuration
of the module and when engaged by the control panel to
communicate via GSM/GPRS.
flashing red LED:
in all other conditions.
DL3 Green LED:
module serial communication Lights up briefly when
the module communicates with the control panel.
DL4 Green LED:
module serial communication Lights up briefly when
the module communicates with the control panel.
DL5
Red LED off:
indicates that there is no signal (e.g. antenna or
SIM card missing)
Red LED on:
active radio connection. Four different levels
of strength indicate the level of GSM signal received. If this
indicator is lit, the module is capable of operating.
(from control panel Fw version 2.2.1, this indication is only visible
with "service" jumper JP7 inserted).
Name Function
P1
If disconnected, the LEDs go off
P2
Reserved
P3
Reserved
Features Value
Types of alarm transmission for
which the device is suitable
ATS2 according to EN50131-1
Generation and/or transmission
times of alarm messages
voice messages:
10 sec.
e-mail:
10 sec without image / 90
sec with image
MMS:
90 sec.
Times for generating a reply signal
(when used)
CONTACT ID:
times according to
standard SIA DC-05-1999.09