![Comelit VEDO10 Technical Manual Download Page 5](http://html1.mh-extra.com/html/comelit/vedo10/vedo10_technical-manual_2640394005.webp)
5
1. Introduction to the system
Vedo
is a modern, practical I&HAS (Intrusion and Hold Up alarm
system) capable of meeting the technical and performance
requirements of modern security systems to the best effect. The Vedo
system allows the creation of systems that require up to 68 individually
balanced standard zones with triple balance, which can be assigned to
a maximum of 8 areas.
The system integrates home automation functions that do not influence
the behaviour of the alarm system.
The control panel is enclosed in a compact housing, which also
accommodates the power supply unit. According to system
requirements, it is possible to equip the control panel card directly with
a module for GSM communication, a messages / voice control module
and a module for communication on IP protocol.
The connectors for powering the control panel are routed from the
power supply unit.
Inside the metal housings it is possible to accommodate 2 standard
input/output expansions. In the plastic housings it is possible to fit
2 8IO expansion modules or 1 8IO expansion module and a radio
expansion. The expansion modules are connected to the Bus.
The system comprises a master unit (the control panel) and a certain
number of slave units (the peripherals on the Bus). Regardless
of system activation status, the control panel's task is to query the
peripheral units periodically to determine correct operation and obtain
information about system status. Each peripheral component is
equipped with local intelligence, which enables it to perform a certain
number of tasks independently and, at the request of the control panel,
communicate its status and any information relating to its specific
peripheral functions.
Communication between the control panel and the expansions
takes place by means of a standard RS485 Bus. The control
panel's standard communication speed is set to 38400 baud.
The modules are all connected to the same Bus, and are
recognisable by their unique address. Depending on the
peripheral, this address can be configured by physical means
(e.g. DIP switches as on the input and output expansions) or by
means of a software configuration (e.g. LCD keypads).
The control panel is supplied with a built-in digital dialler.
The control panel can be programmed directly from the keypad or,
more easily, by means of dedicated software. The audio messages
can be modified only by using the programming software from a PC.
The association of zones to areas and partial subgroups of areas
allows total, partial or selective activation of the system, according to
the authorisations assigned (at the configuration stage) to the user
who performs the operations.
Each input event can be associated with multiple outputs, thus
potentially involving all the outputs configured at the installation stage.
The flexibility of this arrangement makes it possible to adapt the control
panel to the most wide-ranging requirements.
1.1 DESCRIPTION OF SYSTEM COMPONENTS
1.2 GENERAL
1.1.1 Communication standard
1.1.2 Addressing the modules
INPUTS / OUTPUTS / BALANCING
VEDO10
VEDO34
VEDO34M
VEDO68
VEDO68M
Control Panel Inputs
8 + 1 24h
Maximum Number of Inputs
18 (2wire+8radio)
(max 16 radio)
34 (mixed)
34 (mixed)
68 (64Radio)
68 (64Radio)
Control Panel Outputs
3: 1Relay 3A@24V + 2oc 100mA
Maximum Number Outputs (wired +radio)
16
36
36
50
50
Double Function
No
Yes
Yes
Yes
Yes
Balance Type
NO, NC, Single,
Double, Triple, Triple
with jamming
NO, NC, Single, Double, Triple, Triple with jamming, Double zone, Double zone with end of line
PROGRAMMING / MAINTENANCE
VEDO10
VEDO34
VEDO34M
VEDO68
VEDO68M
Programming/Reading of options in local/
remote mode
Yes
Central programming
USB/LAN
Programming from Keypad or Vedo Touch
with emulated keypad
Yes
Programmable test call
Yes
Remote maintenance
Yes with IP card
Periodic test call
Yes on digital dialler
USER CODES / KEYS / REMOTE CONTROLS
VEDO10
VEDO34
VEDO34M
VEDO68
VEDO68M
User Code
8
32
32
50
50
Installer Code
2
5
5
5
5
Manufacturer Code
1
Remote controls
11
38
38
56
56
Keys
11
38
38
56
56
COMPATIBLE DEVICES / NUMBER OF DEVICES SUPPORTED
VEDO10
VEDO34
VEDO34M
VEDO68
VEDO68M
Plastic housing
Yes
Yes
No
Yes
No
Metal housing
No
No
Yes
No
Yes
Power supply unit
PSU15
PSU15
PSU15
PSU50
PSU15
PSU15
PSU50
Maximum number power supply stations
2
4
4
8
8
Number of IN/OUT expansions
0
8
8
12
12
RFID readers
2
8
8
8
8
√
IMPORTANT: no two components of the same type and
with the same logical address must be present on the bus.
For example, there cannot be two or more keypads with
the same address. Should this happen, the system will be
unable to function correctly and will generate a bus error.
TAB_caratteristiche centrale
1.2.1 Main system specifications: