![Comelit VEDO10 Technical Manual Download Page 12](http://html1.mh-extra.com/html/comelit/vedo10/vedo10_technical-manual_2640394012.webp)
12
3. Technical and installation specifications
3.1 BOXPLASTIC
A standard-compliant connection to the electric power
network must be provided.
If the control panel is already assembled, you will have
to remove the electronic cards and the power supply unit
from the housing, so as not to risk damaging them
For standard-compliant installation, prepare the cables and leads
necessary for wiring the system as indicated on page. 9.
In order to guarantee Grade 2 certification according to EN50131-1
the tamper must be mounted and configured correctly
3.2 BOXMETAL
A standard-compliant connection to the electric power
network must be provided.
For standard-compliant installation, prepare the cables and leads
necessary for wiring the system as indicated on page 10-11
In order to guarantee Grade 2 certification according to EN50131-1
the tamper must be mounted and configured correctly.
For the instructions for mounting the housing, see page 37
For the instructions for mounting the housing, see page 39
Art. BOXPLASTIC complies with standards EN50131-1,
EN50131-3, EN50131-6, EN50136-1-1, EN50136-2-1, EN
60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013,
EN50130-4
Art. BOXMETAL complies with standards EN50131-1,
EN50131-3, EN50131-6, EN50136-1-1, EN50136-2-1, EN
60950-1:2006 + A11:2009 + A1:2010 + A12:2011, EN50130-4)
3.1.1 Technical specifications
3.1.2 Installation
3.2.2 Installation
3.2.1 Technical specifications
Features Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
280 x 260 x 80 mm
Weight
803g (h micro fixing
screws)
Operating temperature and Operating
humidity
-10° / + 55° with warm dry air
-10° / + 40° C with max + 93% RH
(not condensed)
Certifiable safety grade
2 according to EN50131-1*
Environmental class
II according to EN50131-1
Features Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
315 x 440 x 95 mm
Weight
3250 g (h fixing supports)
Operating temperature and Operating
humidity
-10° / + 55° with warm dry air
-10° / + 40° C with max + 93% RH
(not condensed)
Certifiable safety grade
2 according to EN50131-1*
Environmental class
II according to EN50131-1
* Respecting any indications for installation
* Respecting any indications for installation