DIP switches 1 to 6 (of SW1) are for addressing the module
on the bus. On the current version, only addresses 1 to 12 are
used, so DIP switches 5 and 6 must be left on OFF.
TERMINAL BLOCK M1
TERMINAL BLOCK M2
ADDRESSING
SETTING THE SPEED OF THE CARD ON THE BUS
Name Function
V+
Power supply positive input
V-
Power supply negative input
A
RS485 data bus - A
B
RS485 data bus - B
Name Function
V+ AUX
Power supply positive output
V-
Power supply negative - output reference
I1
Input 1 / Output 1
I2
Input 2 / Output 2
V-
Power supply negative input / Inputs reference
I3
Input 3 / Output 3
I4
Input 4 / Output 4
I5
Input 5 / Output 5
I6
Input 6 / Output 6
V-
Power supply negative input / Inputs reference
I7
Input 7 / Output 7
I8
Input 8 / Output 8
No.
DIP1
DIP2
DIP3
DIP4
DIP5
DIP6
1
OFF
OFF
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
OFF
OFF
4
ON
ON
OFF
OFF
OFF
OFF
5
OFF
OFF
ON
OFF
OFF
OFF
6
ON
OFF
ON
OFF
OFF
OFF
7
OFF
ON
ON
OFF
OFF
OFF
8
ON
ON
ON
OFF
OFF
OFF
9
OFF
OFF
OFF
ON
OFF
OFF
10
ON
OFF
OFF
ON
OFF
OFF
11
OFF
ON
OFF
ON
OFF
OFF
12
ON
ON
OFF
ON
OFF
OFF
BAUD
DIP7
DIP8
9600
OFF
OFF
38400
ON
OFF
57600
OFF
ON
115200
ON
ON
Note that the standard speed of the bus for VEDO control
panels is 38400 baud.
Name
Flashing
Function
DL1
fast
(50ms ON / 50ms OFF)
expansion connected
slow
(200ms ON / 200ms OFF)
expansion not connected
LED MEANINGS
MOUNTING
3.9.3 Bidirectional radio expansion on bus (Art.
VEDORF)
The modules operate in bidirectional mode (reception and
transmission). This makes it possible to associate radio
controls, radio alarm sensors (contacts and/or volumetric
detectors) and supervised wireless sirens to the control panel.
1.
Dip Switch
2.
Anti-tear tamper
3.
Anti-tamper tamper
Holes for fixing the VEDORF card to the metal housing Art. BOXMETAL.
MAIN FEATURES
• Up to 32 radio zones per module
• Up to 16 radio outputs (including max 8 sirens)
• Up to 8 radio sirens
• Possibility of bidirectional communication
• Operating frequency in 868 MHz band, FSK mode
• Sensor and siren status monitoring
• Separate management of intruder and sabotage alarms
• Radio device power supply monitoring, including sirens
• Monitoring
TECHNICAL SPECIFICATIONS
Features Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
126 x 80 x 32 mm (in the housing)
Weight
131g with housing and screws for fixing
to the wall
29g card alone
Consumption (min./max.)
55mA medium, 60mA max
Operating voltage
10 - 15 V
Operating temperature and
Operating humidity
-10° / + 55° with warm dry air
-10° / + 40° C with max + 93% RH (not
condensed)
Certifiable safety grade
2 according to EN50131-1*
Device Type
TYPE B according to standard EN50131-3
Environmental class
II according to EN50131-1
Art. VEDORF complies with standards EN50131-1,
EN50131-3, EN50131-5-3
* Respecting any indications for configuration and installation
CONFIGURATION JUMPERS
Name Function
JP1
If activated, enables 485 bus terminal resistor
JP3
Reserved
JP6
If activated, disables anti-removal (anti-tear) tamper
JP7
If activated, disables anti-opening tamper
The article VEDO8I8O can be installed in:
• plastic housing Art. BOXPLASTIC (see page 38)
• plastic housing for expansion (see page 28, 47)
• metal housing Art. BOXMETAL (see page 39)
CONFIGURATION JUMPERS
Name Function
JP1
If activated, disables anti-removal (anti-tear) tamper
JP2
If activated, disables anti-opening tamper
JP4
If activated, enables 485 bus terminal resistor