71
EXTRAORDINARY MAINTENANCE
5.
With the brush head in a high position remove the right brush head casing (04), uncoupling
the retention hinges (05).
6.
Remove the brush to be replaced from the tunnel.
7.
Insert the brush (the side with 5 teeth) in the tunnel until it couples with the drive hub on the
opposite side of the tunnel.
ATTENTION: Pay attention to the direction of the brush bristles during
assembly, the cusp of the brush viewed from the above should be towards the
front of the machine.
8.
Insert the idler wheel of the right brush head casing in the brush.
9.
Secure the right casing (04) to the brush head using the retention hinges (05).
10.
Clean the splash guard rubber on the left side of the brush head unit well with a wet cloth
and on the right casing.
11.
Repeat the operations in reverse order to reassemble all the parts.
Check the state of wear of the side splash guard blades and in the event of excessive wear replace
the splash guard blades. Read the section “REPLACING THE SIDE SPLASH GUARD BLADE
(Innova70 S version)” for replacing the rubber blade.
69.
REPLACING THE BRUSH HEAD CARTER (Innova 65B - Innova 75B - Innova 85B - Innova
100B versions)
When the brush head casing is in a good condition it guarantees a better cleaning of the floor as
well as a longer brush motor life. To replace the brush, proceed as follows:
1.
Take the machine to the designated machine maintenance area; use the switch on the
instrument panel to select the “TRANSPORT” program (A).
2.
Block the machine in place by engaging the parking brake, press the pedal (01) and block it
with the lever (02) at the rear of the steering column (read the section “PARKING BRAKE AND
SERVICE BRAKE”).
ATTENTION: users are advised to always wear protective gloves, to avoid the risk
of serious injury to hands.
3.
Turn the main machine switch to "0" by turning the key (03) a quarter rotation to the left.
4.
Remove the key from the instrument panel.
ATTENTION: This operation must be carried out by qualified personnel, using
suitable equipment. An incorrect connection may cause the machine to
malfunction.