EXTRAORDINARY MAINTENANCE
Proceed as follows for replacing the rear rubber blade of the squeegee body:
1.
Turn the wing nuts (10) in the horizontal position.
2.
Remove the front rubber-pressing blades (11).
3.
Remove the rubber (12) and replace it.
4.
Proceed in reverse to replace the rubber.
64. ADJUSTING THE SQUEEGEE (Innova 60B versions)
Careful adjustment of the height between the squeegee rubber and the floor guarantees better
drying and cleaning of the floor as well as a longer vacuum motor life. To regulate the squeegee
rubber proceed as follows:
1.
Bring the brush head unit into contact with the floor, turn the lever (01) on the rear of the
steering column clockwise.
2.
Bring the squeegee into contact with the floor, turn the lever (02) on the rear of the steering
column anti-clockwise.
3.
Remove the parking brake, turn the lever (03) clockwise. In the control panel the red
indicator light incident to the parking symbol “P” will go out.
ATTENTION: If you try to move forward with the parking brake engaged, the
machine will not move because the motor wheel is disengaged electrically
when the parking brake is active.
4.
Adjust the flow of detergent coming out by using the knob (04) on the rear of the steering
column.
5.
By pressing the forward movement pedal (05), the brushes and the vacuum motor start and
the machine starts to move.