51
DAILY MAINTENANCE
2.
Block the machine in place by engaging the parking brake, press the pedal (01) and block it
with the lever (02) at the rear of the steering column (read the section “PARKING BRAKE
AND SERVICE BRAKE”).
3.
Turn the main machine switch to "0" by turning the key (03) a quarter rotation to the left.
4.
Remove the key from the instrument panel.
ATTENTION: users are advised to always wear protective gloves, to avoid the risk
of serious injury to hands.
5.
Remove the drainage tube (04) of the solution tank from the clamps, it is located on the left
side of the machine.
6.
Put the tube on the drainage surface and unscrew the cap.
7.
Repeat the operations in reverse order to reassemble all the parts.
ATTENTION: The place this operation is carried out should comply with current
environmental protection regulations.
48. DRAINING THE SOLUTION TANK (Innova 70S versions)
Proceed as follows to empty the solution tank:
1.
Take the machine to the designated machine maintenance area; use the switch on the
instrument panel to select the “TRANSPORT” program (A).
2.
Block the machine in place by engaging the parking brake, press the pedal (01) and block it
with the lever (02) at the rear of the steering column (read the section “PARKING BRAKE
AND SERVICE BRAKE”).
3.
Turn the main machine switch to "0" by turning the key (03) a quarter rotation to the left.
4.
Remove the key from the instrument panel.
ATTENTION: users are advised to always wear protective gloves, to avoid the risk
of serious injury to hands.