58
WEEKLY MAINTENANCE
55. CLEANING THE RECOVERY TANK
The careful cleaning of the recovery tank guarantees a longer machine life. Proceed as follows to
clean the recovery tank:
1.
Take the machine to the designated machine maintenance area; use the switch on the
instrument panel to select the “TRANSPORT” program (A).
2.
Block the machine in place by engaging the parking brake, press the pedal (01) and block it
with the lever (02) at the rear of the steering column (read the section “PARKING BRAKE
AND SERVICE BRAKE”).
3.
Turn the main machine switch to "0" by turning the key (03) a quarter rotation to the left.
4.
Remove the key from the instrument panel.
ATTENTION: users are advised to always wear protective gloves, to avoid the risk
of serious injury to hands.
5.
Remove the drainage tube of the recovery tank from the clamps, it is located at the rear of
the machine, unscrew the cap and lay it on the ground.
6.
Grip the handle on the right side of the recovery tank.
7.
Lift the recovery tank until it hooks to the safety clamp at the first point.
8.
Raise the cap (04) until the hook (05) is secured to the prop (06) of the recovery tank.
9.
Rinse the inside with a jet of water, if necessary use a spatula to remove the sludge that has
accumulated at the bottom of the tank.
10.
Repeat the operations in reverse order to reassemble all the parts.
ATTENTION: The place this operation is carried out should comply with current
environmental protection regulations.
56. CLEANING THE SOLUTION TANK (Innova 65B – Innova 75B – Innova 85B – Innova 100B –
Innova 70BTO versions)
The careful cleaning of the solution tank guarantees a longer machine life. Proceed as follows to
clean the solution tank:
1.
Take the machine to the designated machine maintenance area; use the switch on the
instrument panel to select the “TRANSPORT” program (A).