6.4.9

Menu5 - P-F = Maintenance timer

6.4.10

Menu6 - CnF = Compressor configuration

Into this menu you can set the maintenance timer.

Parameter Description

Setting range

Default Password

CAF

Change air filter

100 ÷3000

1.500 h

1

COF

Change oil filter

100 ÷ 10000

1.500 h

1

CSF

Change separator filter

100 ÷ 10000

1.500 h

1

C--

Change oil

100 ÷ 10000

1.500 h

1

C-h

Check compressor

100 ÷ 10000

500 h

1

bL

Lubricate motor bearings

100 ÷ 29999

10.000 

h

1

NOTE: The timer counting is related to ON time of RL1 and it comes 

backwards; when the timer reaches 0, it goes on as negative counting. The 

hours storage comes every 15 minutes: if during the counting the power 

goes off, the part of 15 minutes is lost.

If you set C-h = 10000 the related maintenance message is not detected.

By changing the set value the residual time is recalculated.

Example: CAF, set 2000h, the counter is 1600, it means 400h has passed 

from reset. If yu change the set, for example 3000, the counter will change 

into 2600.

Parameter Description

Setting range

Default Password

r--

Restart Low voltage

0 (manual)  1 (automatic)

0

1

FAD

Air flow

1000 ÷ 10000 lt/min.

1000

0

con

Connection

0 (single) - 1 (Master/Slave)

2 (Multiunit Slave)

0

1

nc

Compressor no.

0 ÷ 32

1

1

OfL

Working mode

0 ÷ 1

0

1

MEANING OF THE PARAMETERS SETTING

r--:  0: when the power supply to the controller goes down 9.0Vac, the 

compressor switches off; when the power comes back over 10.5Vac 

the display visualizes the alarm code A07 keeping OFF status; the 

compressor must be manually restarted by the start button.

 

1: when the power supply to the controller goes down 9.0Vac, the 

compressor switches off; when the power comes back over 10.5Vac, 

the compressor starts automatically once the time t05 without 

visualizing any alarm.

FAD:  here you can set the nominal air flow of the compressor.

 

This parameter is used on Multiunit operation by Logik33S / Logik200 

to select the more efficient compressor according the pressure drop 

in the net.

con:  this parameter allows to set the compressor operation according the 

followings:

 

0 (single) = compressor works standing alone.

 

1 (Master/Slave) = the compressor works as Slave unit (serial 

communication) into a compressors system all having Logik 

controllers on board.

 

2 (Multiunit Slave) = the compressor works according Master/Slave 

operation (serial communication) together with another compressor 

with Logik controller on board.

nc:  in case of serial communication with other compressors (compressors 

net), here you must combine the number of the unit to detect the 

controller into the net.

OfL:  this parameter is visualized only if Multiunit operation has been 

enabled. It allows to take the compressor out of the compressors 

management without stopping the entire system: i.e. in case of serve 

maintenance on the compressor.

 

0 (Multiunit operation available) = the compressor is managed into 

Multiunit operation.

 

1 (Multiunit operation not available) = the compressor is not managed 

into Multiunit operation; it works standing alone by its own internal 

pressure sensor.

ESPAÑOL

6.4.9

Menù5 - P-F = Temporizador de mantenimiento

6.4.10

Menù6 - CnF = Configuración del compresor

Este menú permite definir los intervalos de mantenimiento.

Parámetro Descripción

Configuración

Defecto Contraseña

CAF

Cambio de filtro de aire

100 ÷3000

1.500 h

1

COF

Cambio del filtro de aceite

100 ÷ 10000

1.500 h

1

CSF

Cambio del filtro separador

100 ÷ 10000

1.500 h

1

C--

Cambio de aceite

100 ÷ 10000

1.500 h

1

C-h

Control del compresor

100 ÷ 10000

500 h

1

bL

Lubricación de cojinetes del 

motor

100 ÷ 29999

10.000 

h

1

NOTE: la cuenta del temporizador se refiere al tiempo de ON de RL1 y se 

realiza hacia atrás; cuando la cuenta llega a 0, prosigue en negativo.

La memorización de las horas se produce cada 15 minutos y, por tanto, si, 

durante la cuenta, falta la corriente, se pierde la fracción de los 15 minutos.

El parámetro C-h si se configura en 10000 no genera la alarma de 

mantenimiento correspondiente.

Modificando el valor de set, se vuelve a calcular el tiempo residual.

Ej.: CAF, set 2000h, la cuenta ha llegado a 1600, es decir, han pasado 400h 

del reset. Si se cambia el set y se pone, por ejemplo, 3000, en la cuenta se 

verá 2600.

Parámetro Descripción

Configuración

Defecto Contraseña

r--

Nuevo arranque de baja tensión

0 (manual)  1 (automático)

0

1

FAD

Caudal

1000 ÷ 10000 l/min.

1000

0

con

Conexión

0 (individual)  - 1 (maestro/

esclavo) 

2 (esclavo Multiunit)

0

1

nc

Nº Compresor

0 ÷ 32

1

1

OfL

Modo de trabajo

0 ÷ 1

0

1

SIGNIFICADO DE LOS PARÁMETROS DE CONFIGURACIÓN

r--:  0: si la tensión de alimentación baja del valor de 9.0Vca, el controlador 

se apaga; al volver a subir la tensión del valor de 10.5Vca, el display 

visualiza el código de alarma A07 permaneciendo en OFF; el 

compresor se deberá volver a poner en marcha manualmente con el 

botón de arranque.

 

1: cuando la tensión de alimentación baja del valor de 9.0Vca, el compresor 

se apaga; volverá a ponerse en marcha automáticamente al recuperar la 

tensión por encima de 10.5Vca una vez transcurrido el tiempo configurado 

en el parámetro t05 sin visualizar la alarma de baja tensión.

FAD: En este parámetro se puede configurar la capacidad nominal del 

compresor.

 

Dicho parámetro se utiliza en funcionamiento Multiunit desde los 

controladores Logik33S / Logik200 para la selección del compresor 

más adecuado en función de la variación de la presión en red.

con:  este parámetro permite configurar el funcionamiento del compresor 

en los modos siguientes:

 

0 (individual) = el compresor funciona de forma individual.

 

1 (maestro/esclavo) = el compresor funciona en modo maestro/

esclavo (comunicación vía serial) con otro que también tenga un 

controlador de la serie Logik a bordo.

 

2 (esclavo Multiunit) = el compresor funciona como esclavo 

(comunicación vía serial) en un sistema de máquinas que tenga todos 

los controladores de la serie Logik a bordo.

nc:  en caso de comunicación serial entre varios compresores, red de 

máquinas, en este parámetro se configura el número que se debe 

asociar para el reconocimiento del controlador dentro de la red.

OfL:  este parámetro se visualiza sólo en caso de que se haya activado el 

funcionamiento Multiunit y permite excluir el compresor, en caso, por 

ejemplo, de intervención de mantenimiento, sin tener que parar el 

funcionamiento de todo el sistema.

 

0 (Disponible para Multiunit) = el compresor se incluye en la gestión 

Multiunit.

 

1 (Exclusión del Multiunit) = el compresor se excluye de la gestión 

Multiunit y funciona individualmente con su sensor de presión interno.

Summary of Contents for LP-300 NITROX

Page 1: ...LP 300 600 NITROX LOW PRESSURE COMPRESSOR FOR NITROX MIXES COMPRESSORE A BASSA PRESSIONE PER MISCELE NITROX USE AND MAINTENANCE MANUAL English MANUAL DE USO Y MANTENIMIENTO Espa ol...

Page 2: ...OX MIXES This manual is the property of AEROTECNICA COLTRI SpA Reproduction whole or partial is forbidden IMPORTANT BEFORE USING THE COMPRESSOR READ THIS MANUAL CAREFULLY ESPA OL Apreciado cliente le...

Page 3: ...tenance manual This compressor must not be used before reading the entire use and maintenance manual QUICK GUIDE ESPA OL Operaciones preliminares coloque el compresor en el lugar elegido V ase Cap 5 c...

Page 4: ...lter and the de oiler filter See Chap 7 6 periodically discharge the condenses See Chap 7 11 ESPA OL compruebe en los analizadores de Ox geno c d el porcentaje de Ox geno medido ajuste con el pomo f e...

Page 5: ...N GENERAL 7 1 1 Informaci n preliminar 7 1 2 Requisitos de formaci n de los operadores 7 1 3 Avisos para el uso 7 1 4 Premisa 8 1 5 Garant as 8 1 6 Asistencia 9 1 7 Responsabilidad 9 1 8 Uso previsto...

Page 6: ...compresor secador com presor HP 37 6 2 3 Control de la v lvula de puesta al vac o 37 6 2 4 Control del juego de filtros de protecci n membrana 37 6 2 5 C mo guardar la documentaci n t cnica 37 6 3 Pan...

Page 7: ...ols and their meaning They highlight essential information ESPA OL AVISO Hace referencia a integraciones o sugerencias para un uso correcto del compresor ATENCI N Hace referencia a situaciones de peli...

Page 8: ...ormas de servicio descritas en el presente manual constituyen parte integrante del suministro del compresor Dichas normas est n destinadas al operador formado expresamente para conducir este tipo de c...

Page 9: ...OL a cargo del cliente en cualquier caso la garant a vence autom ticamente caso que el compresor haya sufrido intervenciones por parte de t cnicos no autorizados por AEROTECNICA COLTRI SpA El compreso...

Page 10: ...ins pido que no apoyar la vida Respiraci n de las mezclas del gas que contienen m s del 84 de Nitr geno en las presiones superficiales conducir n a la inconsciencia y pueden causar muerte La descarga...

Page 11: ...aga que el cable no se doble ni pase contra cantos cortantes Se desaconseja usar extensiones El compresor no tiene que ponerse nunca en marcha cuando el cable el ctrico est da ado presenta da os evide...

Page 12: ...uncionamiento del aparato y sus mandos y haber le do y comprendido toda la informaci n t cnica contenida en el presente manual Se proh be utilizar el compresor en condiciones o para usos distintos al...

Page 13: ...eature an alarm system and that prevent the introduction of oxygen percentages above the permitted maximum and or incorrect mixes 2 BASIC INFORMATION ON THE COMPRESSOR 2 1 IDENTIFICATION THE COMPRESSO...

Page 14: ...tes de transportar instalar usar o llevar a cabo cualquier mantenimiento sobre el compresor Debe guardarse atentamente en un lugar conocido por el usuario del compresor los responsables los encargados...

Page 15: ...otective clothing 3 1 3 Emergency equipment ESPA OL El compresor debe ser utilizado exclusivamente por personal cualificado Dicho personaltienelaobligaci ndeconocerlasdisposicionesylafunci ndetodoslos...

Page 16: ...sor Inspect the compressor carefully every day it is used as per the check list given in this manual 3 1 4 Checks and maintenance 3 2 GENERAL PRECAUTIONS ESPA OL AVISO Antes de llevar a cabo cualquier...

Page 17: ...r dispositivo de seguridad Toda operaci n de instalaci n mantenimiento ordinario y extraordinario debe llevarse a cabo con el compresor parado y sin alimentaci n el ctrica Trashaberefectuadolalimpieza...

Page 18: ...eguridad El compresor ha sido proyectado y fabricado seg n las reglas vigentes de la buena t cnica para compresores productores de mezclas Nitrox aire rico de Ox geno Se han respetado las leyes dispos...

Page 19: ...ntilated places if the compressor is installed in a closed area a venting pipe to carry the Nitrogen outside must be installed 2 Electrical dangers Use the machine with suitable insulation especially...

Page 20: ...50 HOURS 1 YEAR LP AIR FILTRATION CHANGE EVERY 250 HOURS 1 YEAR LP AIR FILTRATION CHANGE EVERY 250 HOURS 1 YEAR NITROGEN OUTLET FACTORY SET H E M S HIGHEFFICIENCYMEMBRANESYSTEM NITROX FLOW TO HP COMPR...

Page 21: ...as de protecci n b Obligaci n de llevar los zapatos de protecci n c Obligaci n de llevar los guantes de protecci n d Obligaci n de llevar los auriculares de protecci n e Prohibido quitar los c rteres...

Page 22: ...hours see chapter 7 6 Live electrical circuit danger warning ESPA OL Placa de temperatura del calentador El termostato de la temperatura del calentador ha sido calibrado en la sede de producci n a 40...

Page 23: ...ce the duration of the protection of the membrane filters Nitrox plate for HP compressors Indicates Nitrox flow outlet which must be connected to a high pressure compressor ESPA OL Placa de los filtro...

Page 24: ...tenimiento como falta de aceite limpieza insuficiente ineficiencia del circuito del aire comprimido da os de los tubos flexibles apretado de los tubos tornillos etc Realice esmeradamente los trabajos...

Page 25: ...achine being started or even cause a sudden unexpected start For this reason never use water or steam jets on the compressor 3 5 4 Keeping the compressor clean 3 5 5 Warning signs ESPA OL El mantenimi...

Page 26: ...OS 4 1 1 Compresor de tornillo 4 1 2 Transmisi n 4 1 5 Analizador de Ox geno del compresor 4 1 4 Controlador electr nico 4 1 3 Enfriamiento 4 1 CARACTER STICAS T CNICAS El compresor de tornillo est co...

Page 27: ...on the HP compressor ESPA OL 4 1 7 Analizador de Ox geno remoto para medir el de Ox geno en las botellas 4 1 8 Secador 4 1 9 Armaz n c rter de protecci n 4 1 10 Mezclas Nitrox 4 1 11 Man metros 4 1 6...

Page 28: ...24 18 7 10 25 25 15 15 8 1 1 26 26 23 23 17 17 15 15 28 28 11 12 9 13 3 5 13 ENGLISH 4 2 MACHINE PARTS 1 Frame 2 Control panel 3 Start Stop pushbutton 4 Electronic controller 5 Emergency pushbutton 6...

Page 29: ...50Hz 70 db 890mm 1195mm 305mm LP 300 NITROX LP 600 NITROX kW 7 5 15 Hp 10 20 giri min rpm 2960 2960 V 400 400 690 Hz 50 50 690 A 15 29 giri min rpm 2960 2960 bar 8 8 PSI 12 5 12 5 l min 1070 2200 m3 h...

Page 30: ...EMBRANESYSTEM NITROX NITROX 2 2 3 3 4 4 5 5 6 6 7 7 7 8 8 9 9 10 10 11 11 12 12 1 1 LP 600 LP 300 ENGLISH 4 4 MIXING CIRCUIT 1 Screw compressor 2 Dryer 3 Filters separators set 4 Heater 5 Temperature...

Page 31: ...MU LP300 600 1018 LP 300 600 NITROX 31 76 LP 300 600 EVO NITROX LOGIK 9 ENGLISH 4 5 WIRING DIAGRAM ESPA OL 4 5 ESQUEMA EL CTRICO...

Page 32: ...with the utmost care when lifting transferring and positioning the compressor ESPA OL El compresor est introducido en una caja de cart n colocada sobre un europallet para que pueda ser desplazada y tr...

Page 33: ...ng where daylight is on its own insufficient WARNING Before proceeding with the installation tasks described below read Chapter 3 SAFETY REGULATIONS carefully 5 3 1 Positioning 5 3 INSTALLATION ESPA O...

Page 34: ...Nitrogen content of more than 84 at ambient pressure can cause loss of consciousness and or death ESPA OL Casoqueelcompresorsecoloqueenunlugarquenore nalascaracter sticas de ventilaci n indicadas en e...

Page 35: ...se the hose supplied with the compressor Never use a hose with a cross section smaller than the one on the supplied hose ESPA OL Para conectar el compresor LP NITROX a un compresor de alta presi n con...

Page 36: ...invert or disconnect the ground earth wire yellow green ESPA OL 5 3 5 Conexi n el ctrica El compresor se entrega equipado con cable el ctrico pero sin toma de corriente b Para la conexi n el ctrica es...

Page 37: ...o con cartucho de filtro aire compresor de tornillo cartucho filtro del desaceitador cartucho filtro de aceite cartuchos set filtros de protecci n de la membrana cartucho de filtro aire tubo mezclador...

Page 38: ...ONTROL PANEL 6 4 ELECTRONIC CONTROL WARNING It is forbidden to tamper with the thermostat without authorisation from AEROTECNICA COLTRI tampering shall render the warranty null and void where the comp...

Page 39: ...then the following ESPA OL 2 Del estado de OFF se pasa al estado de ON pulsando el bot n el display visualiza la pantalla siguiente Grupo1 En laVisualizaci n Principal y con presencia de alarma presi...

Page 40: ...s posibles estados del compresor son los siguientes Estado Visualizaci n Iconos Con transductor P00 0 Con presostato P00 1 Espera arranque temporizador t05 Mensaje On alternado con la presi n detectad...

Page 41: ...METER CODE UNITS ESPA OL 6 4 5 Introducci n de contrase a Una vez confirmado el nivel de contrase a se pasa a la selecci n de la primera cifra mediante el bot n y se confirma con entonces empezar a pa...

Page 42: ...iones 6 4 7 Men 3 PH Temperaturas 6 4 8 Men 4 Pt Temporizador de trabajo Son los par metros relativos a la presi n Par metro Descripci n Configuraci n Defecto Contrase a P00 Control presi n 0 transduc...

Page 43: ...iguraci n del compresor Este men permite definir los intervalos de mantenimiento Par metro Descripci n Configuraci n Defecto Contrase a CAF Cambio de filtro de aire 100 3000 1 500 h 1 COF Cambio del f...

Page 44: ...ras con carga n mero de arranques por hora del compresor consumo de aire nominal y liberaci n de software del controlador adem s de los temporizadores de las operaciones de mantenimiento que se deben...

Page 45: ...armas de bloqueo se debe pulsar el bot n con el compresor obligatoriamente en OFF C digo Denominaci n Causa A01 Fase invertida La entrada utilizada para el rel de secuencia de fases se ha abierto IN3...

Page 46: ...l bot n incluso con el compresor en funcionamiento C digo Denominaci n Causa F A Cambio de filtro de aire Tiempo del temporizador CAF transcurrido F 0 Cambio del filtro de aceite Tiempo del temporizad...

Page 47: ...a de carga a vac o a trav s de arranque parada remoto el display visualiza el icono y el mensaje 0ff alternado con la presi n en funci n de la selecci n realizada en el par metro p00 y de la temperatu...

Page 48: ...temperature etc 6 5 1 Control panel 6 5 2 Electronic instrument 6 5 DRYER ESPA OL a Interruptor ON OFF arranque apagado b Instrumento de control electr nico c Display d Tecla acceso a la programaci n...

Page 49: ...D del display viceversa si es excesivamente bajo valor inferior al campo de medici n se representa con la intermitencia del primer LED del display Una posible aver a de la sonda T1 se se ala con el en...

Page 50: ...mediante el interruptor ON OFF arranque apagado Compruebe que el instrumento electr nico est encendido Compruebe que la absorci n el ctrica sea conforme con los datos indicados en la placa Compruebe e...

Page 51: ...SSOR ESPA OL El analizador de Ox geno PRO O2 a ha sido proyectado para medir niveles de Ox geno en la capacidad 0 1 100 de O2 El analizador deber a ser utilizado para comprobar el nivel de Ox geno del...

Page 52: ...O2 with the NITROX Relative humidity Oxygen percentage in atmosphere IMPORTANT The analyser is sensitive to the partial pressure of Oxygen Calibration and Oxygen measurements must always carried out a...

Page 53: ...2 consta de una campana de ajuste del flujo y de una tuber a flexible Sustituci n de la bater a Extraiga los 4 tornillos a ubicados en cada esquina de la unidad y levante la tapa b con cuidado Haga de...

Page 54: ...itive to partial pressure of Oxygen ESPA OL Aunque ha sido proyectado para ser resistente al agua el PRO O2 no deber a sumergirse intencionadamente en l quido y a n menos dejarlo a parte sin protecci...

Page 55: ...ressor it is compulsory for anyone not involved in the running of the compressor to maintain a safety distance of at least 3 metes ESPA OL PELIGRO La presi n m xima de recarga con mezclas de Nitrox de...

Page 56: ...e refill as per the instructions provided in the HP compressor use and maintenance manual ESPA OL PELIGRO Durante la recarga de las botellas compruebe constantemente el porcentaje de Ox geno en el ana...

Page 57: ...r el servicio de Asistencia Clientes de AEROTECNICA COLTRI o por personal calificado 7 MANTENIMIENTO PELIGRO No efect e operaciones de mantenimiento si acaba de apagar el compresor espere a que se enf...

Page 58: ...l De oiler filter Membrane protection filter set Fitting hose leak Stand by valve ESPA OL 7 4 TABLADELOSMANTENIMIENTOSPROGRAMADOS Control o limpieza Cambio AVISO Los intervalos para el mantenimento so...

Page 59: ...rcuito de lubricaci n externo Filtro del aceite obstruido Controle el filtro o sustit yalo La v lvula termost tica no funciona Controle la v lvula o sustit yala La v lvula de seguridad interviene La v...

Page 60: ...aceite hidr ulico presente en el grupo tornillo y en el circuito hidr ulico fluye dentro del dep sito La consecuencia de lo arriba indicado es que la primera puesta en marcha de la m quina sucesiva al...

Page 61: ...arse cada 10 horas de funcionamiento del compresor El nivel del aceite debe hallarse entre el nivel m nimo MIN y m ximo MAX Se recuerda que un exceso de aceite puede causar infiltraciones mientras un...

Page 62: ...l aceite hidr ulico presente en el grupo tornillo y en el circuito hidr ulico fluye dentro del dep sito La consecuencia de lo arriba indicado es que la primera puesta en marcha de la m quina sucesiva...

Page 63: ...arse cada 10 horas de funcionamiento del compresor El nivel del aceite debe hallarse entre el nivel m nimo MIN y m ximo MAX Se recuerda que un exceso de aceite puede causar infiltraciones mientras un...

Page 64: ...ANT If the compressor is used in a dusty environment thefilterchangeintervalshouldbereducedto every100hours ESPA OL El filtro de aspiraci n del aire debe sustituirse cada 250 horas de trabajo o cada a...

Page 65: ...T If the compressor is used in a dusty environment the filter change interval should be reduced to every 50 hours ESPA OL El filtro de ventilaci n de la cabina a debe limpiarse cada 100 horas Para lim...

Page 66: ...cial atenci n al mantenimiento y a la sustituci n del juego de filtros que protegen la membrana Una secuencia err nea de los varios filtros puede causar serios da os a la membrana y a los componentes...

Page 67: ...lterchangeintervalshouldbereducedto every100hours ESPA OL 7 11 DESCARGA DE LA CONDENSACI N La condensaci n se recoge en un bid n a controle el bid n peri dicamente con el fin de evitar el llenado y la...

Page 68: ...aire en salida no se utiliza La v lvula de puesta al vac o cuando entra en funcionamiento baja el consumo de energ a el ctrica del compresor Para comprobar que la v lvula de puesta en vac o entra en...

Page 69: ...tes proceda con la puesta fuera de servicio o el desguace del mismo Dicha operaci n debe efectuarse siguiendo las normativas vigentes 9 DESGUACE PUESTA FUERA DE SERVICIO 9 1 ELIMINACI N DE LOS DESECHO...

Page 70: ...STRO DE LOS MANTENIMIENTOS 10 1 SERVICIO DE ASISTENCIA 10 2 INTERVENCIONES DE MANTENIMIENTO PROGRAMADO 10 3 USO DEL COMPRESOR EN CONDICIONES DIF CILES 10 4 EL CUSTOMER CARE CENTRE El cliente tambi n r...

Page 71: ...S ASSISTANCE SERVICE STAMP TECHNICIAN S SIGNATURE DATE TYPE OF WORK AND NOTES ASSISTANCE SERVICE STAMP TECHNICIAN S SIGNATURE DATE ESPA OL 10 5 BOLET N DE MANTENIMIENTO PROGRAMADO TIPO DE INTERVENCI N...

Page 72: ...idge 0 1 micron E5 20 Filter cartridge active carbon E1 20 Nitrogen release valve Temperature sensor Heater Pressure switch Thermostat Membrane Mixer pipe intake filter Mixer pipe Oxygen sensor remote...

Page 73: ...ridge 0 1 micron E5 20 Filter cartridge active carbon E1 20 Nitrogen release valve Temperature sensor Heater Pressure switch Thermostat Membrane Mixer pipe intake filter Mixer pipe Oxygen sensor remot...

Page 74: ...74 76 LP 300 600 NITROX MU LP300 600 1018 ENGLISH ESPA OL...

Page 75: ......

Page 76: ...AEROTECNICA COLTRI Spa Via Colli Storici 177 25015 DESENZANO DEL GARDA BS ITALY Tel 39 030 9910301 Fax 39 030 9910283 www coltri com MU LP300 600 1018...

Reviews: