WARNING:

-  This manual must be read carefully before transporting, 

installing, using or carrying out any maintenance on the 

compressor.

-  It must be preserved carefully in a place known to 

compressor users, managers and all transport/installation/

maintenance/repair/final dismantling personnel.

- This manual indicates the purposes for which the 

compressor can be used and gives instructions for its 

transport, installation, assembly, adjustment and use. It 

also provides information on maintenance tasks, ordering 

spare parts, residual risks and staff training.

-  It should be born in mind that the use and maintenance 

manual can never replace proper experience; some 

maintenance jobs are particularly difficult and in this 

regard the manual only offers general guidelines on 

the most important tasks, which must be carried out 

by personnel with proper training (e.g. acquired during 

training courses run by the manufacturer).

-  This manual is an integral part of the compressor and must 

be stored in a suitable container near the compressor until 

its final demolition. If the manual is lost or damaged a copy 

can be requested from the manufacturer.

-  Make sure all users have understood the regulations for 

use and the meaning of the symbols on the compressor.

-  Observance of these technical instructions can prevent 

accidents: instructions have been drawn up in compliance 

with EEC Machinery Directive 2006/42/CE and subsequent 

amendments.

-  In any case always observe national safety regulations.

-  Do not remove or damage guards, labels or notices, 

especially those required by law.

-  The adhesives attached to the compressor are there for 

safety purposes. They must be replaced if they become 

illegible.

-  This manual reflects the technical knowledge available 

at the time the compressor was sold and cannot be 

considered inadequate simply because updated at a later 

time on the basis of new experience.

-  The manufacturer reserves the right to update products 

and manuals, without any obligation to update preceding 

products or manuals except in exceptional circumstances.

-  To request or receive any updates or additions to this use 

and maintenance manual (which shall be considered an 

integral part of the manual) apply via the contact numbers 

given in section “1.6 Assistance”.

-  Should you have any other queries or suggestions as to how 

to improve the manual please contact the manufacturer.

-  Should you sell the compressor AEROTECNICA COLTRI 

invites you to provide us with the details of the new owner 

so that any new additions to the manual can be sent on.

2.2

GENERAL INSTRUCTIONS

ESPAÑOL

ATENCIÓN:

-  El presente manual debe leerse muy atentamente antes 

de transportar, instalar, usar o llevar a cabo cualquier 

mantenimiento sobre el compresor.

-  Debe guardarse atentamente en un lugar conocido por el 

usuario del compresor, los responsables, los encargados 

del transporte, instalación, uso, mantenimiento, reparación 

y desguace final.

-  El presente manual indica el uso previsto del compresor 

y facilita instrucciones para el transporte, la instalación, 

el montaje, la regulación y el uso del compresor. Facilita 

información para las intervenciones de mantenimiento, el 

pedido de recambios, la presencia de riesgos residuos y la 

formación del personal.

-  Es oportuno recordar que el manual de uso y mantenimiento 

no puede sustituir nunca a una experiencia adecuada del 

usuario; para algunas operaciones de mantenimiento 

especialmente difíciles, el presente manual constituye un 

memorando de las principales operaciones que deben 

efectuar operadores con preparación específica adquirida, 

por ejemplo, asistiendo a cursos de formación en la sede 

del fabricante.

-  El presente manual debe considerarse parte integrante del 

compresor y debe guardarse junto a éste, en un contenedor 

adecuado, hasta la demolición final del aparato. Si se 

pierde o se daña, pida otra copia al fabricante.

-  Asegúrese de que todos los usuarios hayan comprendido 

bien las normas de uso y el significado de los posibles 

símbolos indicados en el compresor.

- Los accidentes pueden evitarse siguiendo estas 

instrucciones técnicas redactadas según la directiva 

máquinas 2006/42/CE y sucesivas integraciones.

-  En cualquier caso es necesario consultar y respetar siempre 

las normas de seguridad nacionales.

-  No extraiga ni dañe las protecciones, las etiquetas y ni el 

texto, especialmente el impuesto por la ley.

-  En el compresor se han aplicado tarjetas adhesivas cuyo 

objetivo es hacer que el uso resulte más seguro. Por eso es 

muy importante sustituirlas si son ilegibles.

-  El presente manual refleja el estado de la técnica al 

momento de la comercialización del compresor y no 

puede considerarse inadecuado sólo porque haya sido 

sucesivamente actualizado en base a nuevas experiencias.

-  El fabricante tiene el derecho de actualizar la producción 

y los manuales cuando lo considere oportuno, sin estar 

obligado a actualizar la producción o los manuales 

anteriores, excepto en casos excepcionales.

-  Para solicitar o recibir actualizaciones del manual de 

uso y mantenimiento o posibles integraciones que 

se considerarán parte integrante del manual, envíe la 

solicitud a los números telefónicos indicados en el párrafo 

“1.6 Asistencia”.

-  Póngase en contacto con el fabricante para obtener más 

información y para hacerle llegar posibles propuestas de 

mejora del manual.

-  AEROTECNICA COLTRI le invita, en caso de cesión del 

aparato, a señalar la dirección del nuevo propietario con el 

fin de facilitar la transmisión de posibles integraciones del 

manual al nuevo usuario.

2.2

INSTRUCCIONES GENERALES

Summary of Contents for LP-300 NITROX

Page 1: ...LP 300 600 NITROX LOW PRESSURE COMPRESSOR FOR NITROX MIXES COMPRESSORE A BASSA PRESSIONE PER MISCELE NITROX USE AND MAINTENANCE MANUAL English MANUAL DE USO Y MANTENIMIENTO Espa ol...

Page 2: ...OX MIXES This manual is the property of AEROTECNICA COLTRI SpA Reproduction whole or partial is forbidden IMPORTANT BEFORE USING THE COMPRESSOR READ THIS MANUAL CAREFULLY ESPA OL Apreciado cliente le...

Page 3: ...tenance manual This compressor must not be used before reading the entire use and maintenance manual QUICK GUIDE ESPA OL Operaciones preliminares coloque el compresor en el lugar elegido V ase Cap 5 c...

Page 4: ...lter and the de oiler filter See Chap 7 6 periodically discharge the condenses See Chap 7 11 ESPA OL compruebe en los analizadores de Ox geno c d el porcentaje de Ox geno medido ajuste con el pomo f e...

Page 5: ...N GENERAL 7 1 1 Informaci n preliminar 7 1 2 Requisitos de formaci n de los operadores 7 1 3 Avisos para el uso 7 1 4 Premisa 8 1 5 Garant as 8 1 6 Asistencia 9 1 7 Responsabilidad 9 1 8 Uso previsto...

Page 6: ...compresor secador com presor HP 37 6 2 3 Control de la v lvula de puesta al vac o 37 6 2 4 Control del juego de filtros de protecci n membrana 37 6 2 5 C mo guardar la documentaci n t cnica 37 6 3 Pan...

Page 7: ...ols and their meaning They highlight essential information ESPA OL AVISO Hace referencia a integraciones o sugerencias para un uso correcto del compresor ATENCI N Hace referencia a situaciones de peli...

Page 8: ...ormas de servicio descritas en el presente manual constituyen parte integrante del suministro del compresor Dichas normas est n destinadas al operador formado expresamente para conducir este tipo de c...

Page 9: ...OL a cargo del cliente en cualquier caso la garant a vence autom ticamente caso que el compresor haya sufrido intervenciones por parte de t cnicos no autorizados por AEROTECNICA COLTRI SpA El compreso...

Page 10: ...ins pido que no apoyar la vida Respiraci n de las mezclas del gas que contienen m s del 84 de Nitr geno en las presiones superficiales conducir n a la inconsciencia y pueden causar muerte La descarga...

Page 11: ...aga que el cable no se doble ni pase contra cantos cortantes Se desaconseja usar extensiones El compresor no tiene que ponerse nunca en marcha cuando el cable el ctrico est da ado presenta da os evide...

Page 12: ...uncionamiento del aparato y sus mandos y haber le do y comprendido toda la informaci n t cnica contenida en el presente manual Se proh be utilizar el compresor en condiciones o para usos distintos al...

Page 13: ...eature an alarm system and that prevent the introduction of oxygen percentages above the permitted maximum and or incorrect mixes 2 BASIC INFORMATION ON THE COMPRESSOR 2 1 IDENTIFICATION THE COMPRESSO...

Page 14: ...tes de transportar instalar usar o llevar a cabo cualquier mantenimiento sobre el compresor Debe guardarse atentamente en un lugar conocido por el usuario del compresor los responsables los encargados...

Page 15: ...otective clothing 3 1 3 Emergency equipment ESPA OL El compresor debe ser utilizado exclusivamente por personal cualificado Dicho personaltienelaobligaci ndeconocerlasdisposicionesylafunci ndetodoslos...

Page 16: ...sor Inspect the compressor carefully every day it is used as per the check list given in this manual 3 1 4 Checks and maintenance 3 2 GENERAL PRECAUTIONS ESPA OL AVISO Antes de llevar a cabo cualquier...

Page 17: ...r dispositivo de seguridad Toda operaci n de instalaci n mantenimiento ordinario y extraordinario debe llevarse a cabo con el compresor parado y sin alimentaci n el ctrica Trashaberefectuadolalimpieza...

Page 18: ...eguridad El compresor ha sido proyectado y fabricado seg n las reglas vigentes de la buena t cnica para compresores productores de mezclas Nitrox aire rico de Ox geno Se han respetado las leyes dispos...

Page 19: ...ntilated places if the compressor is installed in a closed area a venting pipe to carry the Nitrogen outside must be installed 2 Electrical dangers Use the machine with suitable insulation especially...

Page 20: ...50 HOURS 1 YEAR LP AIR FILTRATION CHANGE EVERY 250 HOURS 1 YEAR LP AIR FILTRATION CHANGE EVERY 250 HOURS 1 YEAR NITROGEN OUTLET FACTORY SET H E M S HIGHEFFICIENCYMEMBRANESYSTEM NITROX FLOW TO HP COMPR...

Page 21: ...as de protecci n b Obligaci n de llevar los zapatos de protecci n c Obligaci n de llevar los guantes de protecci n d Obligaci n de llevar los auriculares de protecci n e Prohibido quitar los c rteres...

Page 22: ...hours see chapter 7 6 Live electrical circuit danger warning ESPA OL Placa de temperatura del calentador El termostato de la temperatura del calentador ha sido calibrado en la sede de producci n a 40...

Page 23: ...ce the duration of the protection of the membrane filters Nitrox plate for HP compressors Indicates Nitrox flow outlet which must be connected to a high pressure compressor ESPA OL Placa de los filtro...

Page 24: ...tenimiento como falta de aceite limpieza insuficiente ineficiencia del circuito del aire comprimido da os de los tubos flexibles apretado de los tubos tornillos etc Realice esmeradamente los trabajos...

Page 25: ...achine being started or even cause a sudden unexpected start For this reason never use water or steam jets on the compressor 3 5 4 Keeping the compressor clean 3 5 5 Warning signs ESPA OL El mantenimi...

Page 26: ...OS 4 1 1 Compresor de tornillo 4 1 2 Transmisi n 4 1 5 Analizador de Ox geno del compresor 4 1 4 Controlador electr nico 4 1 3 Enfriamiento 4 1 CARACTER STICAS T CNICAS El compresor de tornillo est co...

Page 27: ...on the HP compressor ESPA OL 4 1 7 Analizador de Ox geno remoto para medir el de Ox geno en las botellas 4 1 8 Secador 4 1 9 Armaz n c rter de protecci n 4 1 10 Mezclas Nitrox 4 1 11 Man metros 4 1 6...

Page 28: ...24 18 7 10 25 25 15 15 8 1 1 26 26 23 23 17 17 15 15 28 28 11 12 9 13 3 5 13 ENGLISH 4 2 MACHINE PARTS 1 Frame 2 Control panel 3 Start Stop pushbutton 4 Electronic controller 5 Emergency pushbutton 6...

Page 29: ...50Hz 70 db 890mm 1195mm 305mm LP 300 NITROX LP 600 NITROX kW 7 5 15 Hp 10 20 giri min rpm 2960 2960 V 400 400 690 Hz 50 50 690 A 15 29 giri min rpm 2960 2960 bar 8 8 PSI 12 5 12 5 l min 1070 2200 m3 h...

Page 30: ...EMBRANESYSTEM NITROX NITROX 2 2 3 3 4 4 5 5 6 6 7 7 7 8 8 9 9 10 10 11 11 12 12 1 1 LP 600 LP 300 ENGLISH 4 4 MIXING CIRCUIT 1 Screw compressor 2 Dryer 3 Filters separators set 4 Heater 5 Temperature...

Page 31: ...MU LP300 600 1018 LP 300 600 NITROX 31 76 LP 300 600 EVO NITROX LOGIK 9 ENGLISH 4 5 WIRING DIAGRAM ESPA OL 4 5 ESQUEMA EL CTRICO...

Page 32: ...with the utmost care when lifting transferring and positioning the compressor ESPA OL El compresor est introducido en una caja de cart n colocada sobre un europallet para que pueda ser desplazada y tr...

Page 33: ...ng where daylight is on its own insufficient WARNING Before proceeding with the installation tasks described below read Chapter 3 SAFETY REGULATIONS carefully 5 3 1 Positioning 5 3 INSTALLATION ESPA O...

Page 34: ...Nitrogen content of more than 84 at ambient pressure can cause loss of consciousness and or death ESPA OL Casoqueelcompresorsecoloqueenunlugarquenore nalascaracter sticas de ventilaci n indicadas en e...

Page 35: ...se the hose supplied with the compressor Never use a hose with a cross section smaller than the one on the supplied hose ESPA OL Para conectar el compresor LP NITROX a un compresor de alta presi n con...

Page 36: ...invert or disconnect the ground earth wire yellow green ESPA OL 5 3 5 Conexi n el ctrica El compresor se entrega equipado con cable el ctrico pero sin toma de corriente b Para la conexi n el ctrica es...

Page 37: ...o con cartucho de filtro aire compresor de tornillo cartucho filtro del desaceitador cartucho filtro de aceite cartuchos set filtros de protecci n de la membrana cartucho de filtro aire tubo mezclador...

Page 38: ...ONTROL PANEL 6 4 ELECTRONIC CONTROL WARNING It is forbidden to tamper with the thermostat without authorisation from AEROTECNICA COLTRI tampering shall render the warranty null and void where the comp...

Page 39: ...then the following ESPA OL 2 Del estado de OFF se pasa al estado de ON pulsando el bot n el display visualiza la pantalla siguiente Grupo1 En laVisualizaci n Principal y con presencia de alarma presi...

Page 40: ...s posibles estados del compresor son los siguientes Estado Visualizaci n Iconos Con transductor P00 0 Con presostato P00 1 Espera arranque temporizador t05 Mensaje On alternado con la presi n detectad...

Page 41: ...METER CODE UNITS ESPA OL 6 4 5 Introducci n de contrase a Una vez confirmado el nivel de contrase a se pasa a la selecci n de la primera cifra mediante el bot n y se confirma con entonces empezar a pa...

Page 42: ...iones 6 4 7 Men 3 PH Temperaturas 6 4 8 Men 4 Pt Temporizador de trabajo Son los par metros relativos a la presi n Par metro Descripci n Configuraci n Defecto Contrase a P00 Control presi n 0 transduc...

Page 43: ...iguraci n del compresor Este men permite definir los intervalos de mantenimiento Par metro Descripci n Configuraci n Defecto Contrase a CAF Cambio de filtro de aire 100 3000 1 500 h 1 COF Cambio del f...

Page 44: ...ras con carga n mero de arranques por hora del compresor consumo de aire nominal y liberaci n de software del controlador adem s de los temporizadores de las operaciones de mantenimiento que se deben...

Page 45: ...armas de bloqueo se debe pulsar el bot n con el compresor obligatoriamente en OFF C digo Denominaci n Causa A01 Fase invertida La entrada utilizada para el rel de secuencia de fases se ha abierto IN3...

Page 46: ...l bot n incluso con el compresor en funcionamiento C digo Denominaci n Causa F A Cambio de filtro de aire Tiempo del temporizador CAF transcurrido F 0 Cambio del filtro de aceite Tiempo del temporizad...

Page 47: ...a de carga a vac o a trav s de arranque parada remoto el display visualiza el icono y el mensaje 0ff alternado con la presi n en funci n de la selecci n realizada en el par metro p00 y de la temperatu...

Page 48: ...temperature etc 6 5 1 Control panel 6 5 2 Electronic instrument 6 5 DRYER ESPA OL a Interruptor ON OFF arranque apagado b Instrumento de control electr nico c Display d Tecla acceso a la programaci n...

Page 49: ...D del display viceversa si es excesivamente bajo valor inferior al campo de medici n se representa con la intermitencia del primer LED del display Una posible aver a de la sonda T1 se se ala con el en...

Page 50: ...mediante el interruptor ON OFF arranque apagado Compruebe que el instrumento electr nico est encendido Compruebe que la absorci n el ctrica sea conforme con los datos indicados en la placa Compruebe e...

Page 51: ...SSOR ESPA OL El analizador de Ox geno PRO O2 a ha sido proyectado para medir niveles de Ox geno en la capacidad 0 1 100 de O2 El analizador deber a ser utilizado para comprobar el nivel de Ox geno del...

Page 52: ...O2 with the NITROX Relative humidity Oxygen percentage in atmosphere IMPORTANT The analyser is sensitive to the partial pressure of Oxygen Calibration and Oxygen measurements must always carried out a...

Page 53: ...2 consta de una campana de ajuste del flujo y de una tuber a flexible Sustituci n de la bater a Extraiga los 4 tornillos a ubicados en cada esquina de la unidad y levante la tapa b con cuidado Haga de...

Page 54: ...itive to partial pressure of Oxygen ESPA OL Aunque ha sido proyectado para ser resistente al agua el PRO O2 no deber a sumergirse intencionadamente en l quido y a n menos dejarlo a parte sin protecci...

Page 55: ...ressor it is compulsory for anyone not involved in the running of the compressor to maintain a safety distance of at least 3 metes ESPA OL PELIGRO La presi n m xima de recarga con mezclas de Nitrox de...

Page 56: ...e refill as per the instructions provided in the HP compressor use and maintenance manual ESPA OL PELIGRO Durante la recarga de las botellas compruebe constantemente el porcentaje de Ox geno en el ana...

Page 57: ...r el servicio de Asistencia Clientes de AEROTECNICA COLTRI o por personal calificado 7 MANTENIMIENTO PELIGRO No efect e operaciones de mantenimiento si acaba de apagar el compresor espere a que se enf...

Page 58: ...l De oiler filter Membrane protection filter set Fitting hose leak Stand by valve ESPA OL 7 4 TABLADELOSMANTENIMIENTOSPROGRAMADOS Control o limpieza Cambio AVISO Los intervalos para el mantenimento so...

Page 59: ...rcuito de lubricaci n externo Filtro del aceite obstruido Controle el filtro o sustit yalo La v lvula termost tica no funciona Controle la v lvula o sustit yala La v lvula de seguridad interviene La v...

Page 60: ...aceite hidr ulico presente en el grupo tornillo y en el circuito hidr ulico fluye dentro del dep sito La consecuencia de lo arriba indicado es que la primera puesta en marcha de la m quina sucesiva al...

Page 61: ...arse cada 10 horas de funcionamiento del compresor El nivel del aceite debe hallarse entre el nivel m nimo MIN y m ximo MAX Se recuerda que un exceso de aceite puede causar infiltraciones mientras un...

Page 62: ...l aceite hidr ulico presente en el grupo tornillo y en el circuito hidr ulico fluye dentro del dep sito La consecuencia de lo arriba indicado es que la primera puesta en marcha de la m quina sucesiva...

Page 63: ...arse cada 10 horas de funcionamiento del compresor El nivel del aceite debe hallarse entre el nivel m nimo MIN y m ximo MAX Se recuerda que un exceso de aceite puede causar infiltraciones mientras un...

Page 64: ...ANT If the compressor is used in a dusty environment thefilterchangeintervalshouldbereducedto every100hours ESPA OL El filtro de aspiraci n del aire debe sustituirse cada 250 horas de trabajo o cada a...

Page 65: ...T If the compressor is used in a dusty environment the filter change interval should be reduced to every 50 hours ESPA OL El filtro de ventilaci n de la cabina a debe limpiarse cada 100 horas Para lim...

Page 66: ...cial atenci n al mantenimiento y a la sustituci n del juego de filtros que protegen la membrana Una secuencia err nea de los varios filtros puede causar serios da os a la membrana y a los componentes...

Page 67: ...lterchangeintervalshouldbereducedto every100hours ESPA OL 7 11 DESCARGA DE LA CONDENSACI N La condensaci n se recoge en un bid n a controle el bid n peri dicamente con el fin de evitar el llenado y la...

Page 68: ...aire en salida no se utiliza La v lvula de puesta al vac o cuando entra en funcionamiento baja el consumo de energ a el ctrica del compresor Para comprobar que la v lvula de puesta en vac o entra en...

Page 69: ...tes proceda con la puesta fuera de servicio o el desguace del mismo Dicha operaci n debe efectuarse siguiendo las normativas vigentes 9 DESGUACE PUESTA FUERA DE SERVICIO 9 1 ELIMINACI N DE LOS DESECHO...

Page 70: ...STRO DE LOS MANTENIMIENTOS 10 1 SERVICIO DE ASISTENCIA 10 2 INTERVENCIONES DE MANTENIMIENTO PROGRAMADO 10 3 USO DEL COMPRESOR EN CONDICIONES DIF CILES 10 4 EL CUSTOMER CARE CENTRE El cliente tambi n r...

Page 71: ...S ASSISTANCE SERVICE STAMP TECHNICIAN S SIGNATURE DATE TYPE OF WORK AND NOTES ASSISTANCE SERVICE STAMP TECHNICIAN S SIGNATURE DATE ESPA OL 10 5 BOLET N DE MANTENIMIENTO PROGRAMADO TIPO DE INTERVENCI N...

Page 72: ...idge 0 1 micron E5 20 Filter cartridge active carbon E1 20 Nitrogen release valve Temperature sensor Heater Pressure switch Thermostat Membrane Mixer pipe intake filter Mixer pipe Oxygen sensor remote...

Page 73: ...ridge 0 1 micron E5 20 Filter cartridge active carbon E1 20 Nitrogen release valve Temperature sensor Heater Pressure switch Thermostat Membrane Mixer pipe intake filter Mixer pipe Oxygen sensor remot...

Page 74: ...74 76 LP 300 600 NITROX MU LP300 600 1018 ENGLISH ESPA OL...

Page 75: ......

Page 76: ...AEROTECNICA COLTRI Spa Via Colli Storici 177 25015 DESENZANO DEL GARDA BS ITALY Tel 39 030 9910301 Fax 39 030 9910283 www coltri com MU LP300 600 1018...

Reviews: