Notes:
Page 59 of 107
SmartLF Gx Service Manual
Turning the 2 screws mounted under the camera housing will move
the ends of the board allowing the CCD to be aligned to the target.
It is far easier to run the PlotWorks program on a laptop, so the
screen can be easily see without obstructions during adjustment.
Connect the scanner to the laptop (or PC if laptop not available)
and power both the PC and the scanner up. If the plotworks
program has not been install it can be done so from either the latest
service CD or for the support site (www.colortracsupport.co.uk)
1.
Fix the target along the scan line using sticky tape to hold in
place. The target needs to have the dotted line down the
middle of the scan gap, with the very ends of the line having
exactly the same distance from the paper hold down bearing
at either end