Page | 62
VASTRAJET
2.
Tub sensor position disturbed
3.
Jetting pump air lock /clogged by
foreign materials
4.
Pump fuse blown
5.
Pump failure or faulty
Case 2:
Check if any of the tub sensor’s
light is ON. This means that:
1.
Sensor is not in range with
respect to the actuator shaft,
correct it
2.
Sensor is faulty, replace it.
Case 3:
Perform the following actions:
1.
Tilt the tub to release the air
2.
Check the water level in the tub
and refill it, if required
Case 4:
Check and replace it, if required.
Case 5:
Replace the pump, if required.
Water
Seepage in
Belt
1.
Sponge roller shape is distorted
2.
Sponge roller or Squeeze roller
movement is jammed
3.
Washing tub is not engaged properly
4.
Glue dryer is not working
Case 1:
Replace the Sponge roller or
bearing, if faulty or distorted.
Case 2:
Check Sponge or Squeeze roller
movement manually, it should be free.
Case 3:
Check the following:
1.
Check Actuator proper elevation
(refer to the Washing Tub Not
Engaging Properly section)
2.
Actuator blot is not aligned
properly, align it.
Case 4:
Refer to the
Heater Not Working
section.
Belt Shifted
Not
Controlled
1.
Shifting control process is not
followed correcting
2.
Shifting control unit is not working
Case 1:
Check the following:
•
Shifting is not controlled using
the Shifting Control switch
•
Shifting control switch is rotated
in wrong direction
Case 2:
Check and change the direction
of the Shifting Control unit, if required.
Negative
Pressure
Drop/Not
Working
1.
Meniscus vacuum switch is OFF
2.
Negative Pressure switch program is
disturbed
3.
Vacuum is not generated by pump
(pump failure)
4.
Any
ink/air
tube
is
having
leakage/cut/loose on fitting joints
5.
Vacuum
pump
connector
is
loose/open from MMCB
Case 1:
Switch ON the meniscus vacuum
switch.
Case 2:
Contact the head office.
Case 3:
Replace the pump.
Case 4:
Replace the ink/air tub or tighten
if loose.
Case 5:
Tighten the Vacuum Pump Conn-
ector or close from MMCB.