Page | 58
VASTRAJET
13. Troubleshooting Guide
Error Name
Reasons
Remedial Actions
Printer Not
Initializing/Ini
-tialization
Incomplete
1.
No Power Supply to Head Board
(beep can be heard)
2.
Servo Driver not ON or faulty or
programmed incorrectly
3.
Carriage Safety switch is activated
4.
Encoder sensor not connected or
faulty (Carriage will top at right)
5.
Main Board is faulty
or it’s settings
are incorrect
6.
Head Board is faulty
7.
Emergency Button is pressed
Case 1:
No Power Supply to Head Board
a)
Check 24 V power supply output
and replace the Power Supply
b)
Check the 24 V Power Supply on
Head Board connector, if there is
no power, then check cable
continuity and replace it, if
required.
Case 2:
Servo Driver not ON or faulty
a)
Check the Red LED on Servo
Driver, if LED is not glow then
check the power connection and
trace the fault.
b)
In case, machine is not initialized
correctly, then contact Head
Office.
Case 3:
Carriage Safety Switch is Activa-
ted
a)
Remove the obstacles, if any
and release the Safety Flaps, if
pressed.
b)
Check the wire connectivity
from switch to relay switch.
c)
Replace the Safety switch, if
faulty.
Case 4:
Encoder Sensor not Connected or
Faulty
Case 5:
Main Board is Faulty or it’s
Settings are Incorrect
a)
No power on Main Board
b)
Check power 24V and 5V on
Main Board
c)
Replace the Main Board, if faulty
Case 6:
Head Board is Faulty
a)
Check 24V power on the Head
Board connector.
b)
Replace the Head Board, if
required.
Case 7:
Emergency Button is Pressed
a)
Release the Emergency Button, if
pressed.
b)
Check 220V on emergency.