BBG-1070-QS Function Menu List and Descriptions
3-16
BBG-1070-QS PRODUCT MANUAL
BBG1070QS-OM (V1.8)
(continued)
• PiP Layout QuickSet Template Presets
(Cascade Mode)
Cascade Mode Using PiP Layout QuickSet Template Presets
Layout QuickSets provide for layouts consisting of symmetrical columns
and rows that are intended for cascade layouts where, for example, an
upstream BBG-1070-QS provides a first column of PiP images, and then
a second BBG-1070-QS provides the second column of PiP images.
The descriptions here describe using the controls and also provide
examples using the controls and the resulting multi-unit cascade setups.
Table 3-1
BBG-1070-QS Function Menu List — continued
The Number of Rows and Number of Columns
drop-downs set the grid format to be used for a
multi-unit, multiviewer setup. Once the number of
rows/columns is set, this is propagated to other PiP
controls on the unit, since this will be a unit global
setting that allows other PiP insertions to conform with
the desired grid layout.
The QuickSet Action field shows a summary of the
configured layout. Click Apply QuickSet to enact the
layout setup.
In this example, a 4-row x 4-column grid is being set up
(which can provide a 16:1 multiviewer layout using four
BBG-1070-QS units, each handling four PiP images).
The Row Position and Column Position drop-downs set
where in the grid the PiP image will be inserted (in this
example, position row 1 / column 1).