11
Parameters
CONTROLLER DIAGNOSTIC TOOL (CDT)
22
5.8 mph (9.3 km/h)
9.8 mph (15.8 km/h)
12.8 mph (20.6 km/h)
14.8 mph (23.8 km/h)
23
5.7 mph (9.2 km/h)
9.7 mph (15.6 km/h)
12.7 mph (20.4 km/h)
14.7 mph (23.7 km/h)
24
5.6 mph (9.0 km/h)
9.6 mph (15.4 km/h)
12.6 mph (20.3 km/h)
14.6 mph (23.5 km/h)
25
5.5 mph (8.9 km/h)
9.5 mph (15.3 km/h)
12.5 mph (20.1 km/h)
14.5 mph (23.3 km/h)
26
5.4 mph (8.7 km/h)
9.4 mph (15.1 km/h)
12.4 mph (20.0 km/h)
14.4 mph (23.2 km/h)
27
5.3 mph (8.5 km/h)
9.3 mph (15.0 km/h)
12.3 mph (19.8 km/h)
14.3 mph (23.0 km/h)
28
5.2 mph (8.4 km/h)
9.2 mph (14.8 km/h)
12.2 mph (19.6 km/h)
14.2 mph (22.9 km/h)
29
5.1 mph (8.2 km/h)
9.1 mph (14.6 km/h)
12.1 mph (19.5 km/h)
14.1 mph (22.7 km/h)
30
5.0 mph (8.0 km/h)
9.0 mph (14.5 km/h)
12.0 mph (19.3 km/h)
14.0 mph (22.5 km/h)
Control Mode
The
control mode
option is used to configure the controller for different modes of speed control operation. Four
modes are avaiable:
• 0 = Standard: Uses maximum speeds defined in the parameters.
• 1 = LIN (Local Interconnect bus) (i.e. Guardian or Visage): Uses maximum speeds assigned to a particular location
or area as defined by the fleet operator; however, these defined speeds can not override maximums set in the
parameters.
• 2 = ES-Protocol (UpLink): Uses maximum speeds assigned to a particular location or area as defined by the fleet
operator; however, these defined speeds can not override previously set values from other
control mode
options. To
avoid this, after changing the
control mode
to 2, cycle power to the controller by placing the Run/Tow Switch in the
TOW position for 30 seconds. Then return it to RUN.
• 3 = Deterrent Demo Mode: Uses maximum speeds defined by the
deterrent demo
setting to demonstrate the
automatic speed control features of Guardian and UpLink.
See Deterrent Demo on page 11-8.
Anti-Tamper
The
anti-tamper
setting defines maximum speed if the Anti-Tamper fault is triggered (e.g. controller is disconnected
from the Guardian or Visage system). These speeds can only be activated if the Control Mode option is set to 1
(Guardian/Visage) and are intended to be a deterrent. Factory default setting is 1.
• 0 = OFF; uses controller configured speed even if the Anti-Tamper fault is triggered
• 1 = 2 mph
• 2 = 0 mph
• 3 = 7 mph
Deterrent Demo
The
deterrent demo
setting defines maximum speed of Control Mode 3.
• 0 = Controller configured speed
• 1 = 10 mph
• 2 = 7 mph
• 3 = 2 mph
WalkAway Deterrent
The
walkaway deterrent
menu item allows the user to turn this function ON or OFF.
Walkaway deterrent
is triggered by
the High Speed WalkAway fault. With it ON, the reverse buzzer will sound immediately upon the key switch being turned
OFF at speeds above 2 mph. With it OFF, the buzzer will cycle on and off at a higher frequency (7.5 Hz vs. 2.5 Hz).
Page 11-8
2019 Transporter Maintenance and Service Manual
Summary of Contents for TransPorter 4
Page 2: ......
Page 271: ...ELECTRIC MAIN HARNESS Wiring Diagrams Electric Main Harness 18 ...
Page 272: ... Page intentionally left blank ...
Page 273: ...ELECTRIC INSTRUMENT PANEL HARNESS Wiring Diagrams Electric Instrument Panel Harness 18 ...
Page 274: ... Page intentionally left blank ...
Page 275: ...ELECTRIC ACCESSORIES HARNESS Wiring Diagrams Electric Accessories Harness 18 ...
Page 276: ... Page intentionally left blank ...
Page 282: ...NOTES ...
Page 283: ...NOTES ...
Page 284: ...NOTES ...
Page 285: ......
Page 286: ......