Before initial operation
4
4
Before initial operation
The 47BA has been configured by Cooper Power Tools. A setting for your specific screw joint
needs must only be made with the TMEB-200 / TMEC controller or a PC by a qualified person.
For more information, refer to the TMEB-200 / TMEB-COM / TMEC programming manual.
4.1
Setting up tool holder
➔
Mount the tool holder on a stable base.
For tool holder with IrDA interface port:
➔
Select the location in such a way that no outside light shines onto the tool holder.
This can inhibit data transmission.
➔
Lay the connection cable in such a way that there is no danger that persons can trip.
4.2
Ambient conditions
4.3
Charging the battery
Charge fully before first use.
Battery is only partly charged when delivered.
➔
Fully charge before first use.
➔
Battery charging temperature: 5 °C to +45 °C (+41 °F to +113 °F)
➔
Follow the safety instructions printed on the battery and charger.
➔
Fully charge new batteries or those not used for a long time.
➔
Do not totally discharge the battery (< 17.5 V).
➔
Protect the battery from impact.
➔
Keep the charger and battery contacts clean and dry.
➔
Protect the battery from moisture.
➔
The battery can remain in the charger when not in use: the self-discharging is very low.
➔
Replace used batteries and recycle them (see 12 Disposal, page 71.)
Ambient temperature
0 °C (32 °F) to m40° C (+104° F)
Humidity
0 to 80 %, not with dew
Working height
up to 1000 m above sea level
WARNING!
Electrical shock, overheating or leakage of corrosive liquid from the battery can occur when
using incorrect chargers or batteries.
➔
Use only original CLECO batteries and chargers.
They are designed for use together.
NOTE
With proper use, the battery can be charged at least 800 (60% capacity) times.
Here, the following is important: