91c_LCD en bedingt.fm, 24.09.2007
P1891E/EN 09/07
21
LCD display
6
6
LCD display
The LCD display on the tool is divided into the result display, status display, operating menu and
system error messages.
6.1
Result display
First line – result:
The status is displayed in alternation with the Application being used.
The LCD display consists of a three lines, each with 6 characters,
to display the status, torque and angle. The result display is updated after the
rundown ends.
OK
Result is OK
NOK
Result is not OK
OFF
Torque transducer offset error
CAL
Torque transducer calibration error
ENC
Angle encoder error
IP
Current overload in output section
IIT
Requested motor output is too high
TMAX
Maximum fastening time exceeded
RC
Rundown canceled by disabled start signal
TS
Depth sensor signal was enabled at start or
was subsequently disabled during the rundown (only for 17BP series)
Tq<
Torque too low
Tq>
Torque too high
A<
Angle too low
A>
Angle too high
Error
Error occurred
Second line – Shut-off torque in Nm:
T
Final torque
Third line – Shut-off angle in degrees:
A
Final angle
For types with wireless transmission, an interrupted data connection to the
TMEB-200 / TMEB-COM / TMEC is indicated by the
symbol at the top right of
the LCD display.
OK
T 12.00
A 100
OK
T 12.00
A 100