12
P1891E/EN 09/07
91b_1_5 en bedingt.fm, 24.09.2007
Scope of supply, transport and storage
2
3.2.1
Function keys
Left function key <F1>
• Confirm error message
➔
Press once.
Programmable: Depending on how the key is programmed, actions can be carried out by
pressing it briefly.
• Exit menu
➔
Press for two seconds.
Right function key <F1>
• Activate menu
➔
Press until the display shows the
Main menu
(for additional information, refer to 6.3 Operating
menu, page 24).
• Select functions, if menu is activated
➔
Press for two seconds. Alternatively, the start button can be pressed.
3.2.2
LED display
The LED display shows the respective operating status and the result of the last fastening
sequence (see 5.2 Operating status, page 19):
Software update
During
Software Update
, the actual programming process is indicated by rapid flashing alternat-
ing at irregular intervals between red and green.
LEDs
Operating status
Result
after screwing cycle
Steady light Green
Active
OK
Steady light Red
Active
NOK
Flashing light Green –
low frequency
Energy saver mode
Off
Sleep
If Linking is selected on TMEB-200 / TMEC:
Flashing light Green –
high frequency
Active / Settings: Linking
Linking OK
Flashing light Red
Active / Settings: Linking
Linking NOK
NOTE